The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Four-Color Colloidal Multiplexing Nanoparticle System
Abstract
Any labeling with multicolor markers can be affected by the autofluorescence of biological tissue due to the UV or blue light excitation sources, or the results are affected by fluorescence resonance energy transfer. In this work, we present novel IR-to-vis upconverting nanoparticles of different rare earth metal dopants. With a single excitation source of 980 nm, four different colors of nanocrystals can be spectrally separated under multiplexing conditions. The particles were phase transferred into polar solvents by means of silica encapsulation and were characterized by transmission electron microscopy, X-ray diffraction, and photoluminescence spectroscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shannon, R. D. (1976) · Acta Crystallographica Section A · doi:10.1107/s0567739476001551 · Cited by 66,145
Perspectives on the Physical Chemistry of Semiconductor Nanocrystals
Alivisatos, A. P. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp9535506 · Cited by 3,595
Cited by
Zheng, W., Huang, P., Tu, D., Ma, E., Zhu, H., & Chen, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00178h · Cited by 894
Non-blinking and photostable upconverted luminescence from single lanthanide-doped nanocrystals
Wu, S., Han, G., Milliron, D. J., Aloni, S., Altoe, V., Talapin, D. V., Cohen, B. E., & Schuck, P. J. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0904792106 · Cited by 710
Chen, G., Ohulchanskyy, T. Y., Kumar, R., Ågren, H., & Prasad, P. N. (2010) · ACS Nano · doi:10.1021/nn100457j · Cited by 632
Li, X., Zhang, F., & Zhao, D. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00163j · Cited by 615
Zhong, Y., Tian, G., Gu, Z., Yang, Y., Gu, L., Zhao, Y., Ma, Y., & Yao, J. (2014) · Advanced Materials · doi:10.1002/adma.201304903 · Cited by 448
Metadata
- Authors
- Ehlert, O., Thomann, R., Darbandi, M., & Nann, T.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-01-04
- Volume
- 2
- Issue
- 1
- Pages
- 120-124
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2008965839
- Cited by
- 331
- References
- 2
- FWCI
- 15.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.