The DOI matches its Crossref record.
Nanometal-Decorated Exfoliated Graphite Nanoplatelet Based Glucose Biosensors with High Sensitivity and Fast Response
Abstract
We report the novel fabrication of a highly sensitive, selective, fast responding, and affordable amperometric glucose biosensor using exfoliated graphite nanoplatelets (xGnPs) decorated with Pt and Pd nanoparticles. Nafion was used to solubilize metal-decorated graphite nanoplatelets, and a simple cast method with high content organic solvent (85 wt %) was used to prepare the biosensors. The addition of precious metal nanoparticles such as platinum (Pt) and palladium (Pd) to xGnP increased the electroactive area of the electrode and substantially decreased the overpotential in the detection of hydrogen peroxide. The Pt-xGnP glucose biosensor had a sensitivity of 61.5+/-0.6 microA/(mM x cm(2)) and gave a linear response up to 20 mM. The response time and detection limit (S/N=3) were determined to be 2 s and 1 microM, respectively. Therefore, this novel glucose biosensor based on the Pt nanoparticle coated xGnP is among the best reported to date in both sensing performance and production cost. In addition, the effects of metal nanoparticle loading and the particle size on the biosensor performance were systematically investigated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Carbon as catalyst and support for electrochemical energy conversion
Trogadas, P., Fuller, T. F., & Strasser, P. (2014) · Carbon · doi:10.1016/j.carbon.2014.04.005 · Cited by 522
Tien, H.-W., Huang, Y.-L., Yang, S.-Y., Wang, J.-Y., & Ma, C.-C. M. (2011) · Carbon · doi:10.1016/j.carbon.2010.12.022 · Cited by 384
Metadata
- Authors
- Lu, J., Do, I., Drzal, L. T., Worden, R. M., & Lee, I.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-09-03
- Volume
- 2
- Issue
- 9
- Pages
- 1825-1832
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2036421175
- Cited by
- 438
- References
- 0
- FWCI
- 32.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.