The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrochemical Biosensor of Nanocube-Augmented Carbon Nanotube Networks
Abstract
Networks of single-walled carbon nanotubes (SWCNTs) decorated with Au-coated Pd (Au/Pd) nanocubes are employed as electrochemical biosensors that exhibit excellent sensitivity (2.6 mA mM(-1) cm(-2)) and a low estimated detection limit (2.3 nM) at a signal-to-noise ratio of 3 (S/N = 3) in the amperometric sensing of hydrogen peroxide. Biofunctionalization of the Au/Pd nanocube-SWCNT biosensor is demonstrated with the selective immobilization of fluorescently labeled streptavidin on the nanocube surfaces via thiol linking. Similarly, glucose oxidase (GOx) is linked to the surface of the nanocubes for amperometric glucose sensing. The exhibited glucose detection limit of 1.3 muM (S/N = 3) and linear range spanning from 10 muM to 50 mM substantially surpass similar CNT-based biosensors. These results, combined with the structure's compatibility with a wide range of biofunctionalization procedures, would make the nanocube-SWCNT biosensor exceptionally useful for glucose detection in diabetic patients and well suited for a wide range of amperometric detection schemes for clinically important biomarkers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214 · cited 1×
“D etection of biomolecules at low concentrations is critically important to the early diagnosis and successful treatment of diseases.(1,2) Electrochemical biosensors developed with nanomaterials offer highly sensitive, realtime detection of clinically important analytes with low power requirements for decentralized te…”
Background
Cited by
Carbon Nanomaterials in Biosensors: Should You Use Nanotubes or Graphene?
Yang, W., Ratinac, K. R., Ringer, S. P., Thordarson, P., Gooding, J. J., & Braet, F. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200903463 · Cited by 1,431
Review: Carbon nanotube based electrochemical sensors for biomolecules
Jacobs, C. B., Peairs, M. J., & Venton, B. J. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.01.009 · Cited by 987
Advances in carbon nanotube based electrochemical sensors for bioanalytical applications
Vashist, S. K., Zheng, D., Al-Rubeaan, K., Luong, J. H. T., & Sheu, F.-S. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2010.10.002 · Cited by 448
Carbon nanotubes: a novel material for multifaceted applications in human healthcare
Kumar, S., Rani, R., Dilbaghi, N., Tankeshwar, K., & Kim, K.-H. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00517a · Cited by 397
Toward High-Performance Digital Logic Technology with Carbon Nanotubes
Tulevski, G. S., Franklin, A. D., Frank, D., Lobez, J. M., Cao, Q., Park, H., Afzali, A., Han, S.-J., Hannon, J. B., & Haensch, W. (2014) · ACS Nano · doi:10.1021/nn503627h · Cited by 312
Self-citation
Metadata
- Authors
- Claussen, J. C., Franklin, A. D., ul Haque, A., Porterfield, D. M., & Fisher, T. S.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-01-05
- Volume
- 3
- Issue
- 1
- Pages
- 37-44
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2139242437
- Cited by
- 242
- References
- 1
- FWCI
- 23.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.