The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Solvation of Carbon Nanotubes in a Room-Temperature Ionic Liquid
Abstract
Single- and double-walled carbon nanotubes in the armchair configuration solvated in the room-temperature ionic liquid 1-ethyl-3-methylimidazolium tetrafluoroborate (EMI + BF 4 − ) are studied via molecular dynamics (MD) computer simulations. Cations and anions show smeared-out, cylindrical shell-like distributions outside of the nanotubes irrespective of the nanotube diameter. The ion distributions inside the nanotubes vary markedly with their diameter. For example, in the case of ( n, n ) single-walled nanotubes, EMI + and BF 4 − ions separately form single-shell zigzag and chiral distributions for (8,8) and (10,10), respectively, while (12,12) develops a second internal solvation structure. The first internal solvation shell of (15,15) nanotubes consists of alternating layers of cations and anions along the nanotube axis. In the azimuthal direction, these cations and anions, respectively, form a pentagonal structure, whereas the corresponding ions for (20,20) show disordered octagonal structures. The smallest nanotube that allows solvent ions inside the tunnel is (7,7) with a diameter of 0.95 nm, which shows a single file distribution of internal ions. Imidazole rings of cations in the first internal and external solvation shells are mainly parallel to the nanotube surface, indicating π-stacking between the nanotubes and EMI + ions there.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ionic liquids: solvent properties and organic reactivity
Chiappe, C., & Pieraccini, D. (2005) · Journal of Physical Organic Chemistry · doi:10.1002/poc.863 · Cited by 1,169
Anomalously Immobilized Water: A New Water Phase Induced by Confinement in Nanotubes
Mashl, R. J., Joseph, S., Aluru, N. R., & Jakobsson, E. (2003) · Nano Letters · doi:10.1021/nl0340226 · Cited by 447
Cited by
Structure and Nanostructure in Ionic Liquids
Hayes, R., Warr, G. G., & Atkin, R. (2015) · Chemical Reviews · doi:10.1021/cr500411q · Cited by 2,293
Capacitive Energy Storage in Nanostructured Carbon–Electrolyte Systems
Simon, P., & Gogotsi, Y. (2013) · Accounts of Chemical Research · doi:10.1021/ar200306b · Cited by 1,486
Zhang, S., Zhang, J., Zhang, Y., & Deng, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00509 · Cited by 659
Microstructural and Dynamical Heterogeneities in Ionic Liquids
Wang, Y.-L., Li, B., Sarman, S., Mocci, F., Lu, Z.-Y., Yuan, J., Laaksonen, A., & Fayer, M. D. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00693 · Cited by 465
At the interface: solvation and designing ionic liquids
Hayes, R., Warr, G. G., & Atkin, R. (2010) · Physical Chemistry Chemical Physics · doi:10.1039/b920393a · Cited by 418
Nanoparticles in ionic liquids: interactions and organization
He, Z., & Alexandridis, P. (2015) · Physical Chemistry Chemical Physics · doi:10.1039/c5cp01620g · Cited by 395
Ionic liquids confined in porous matrices: Physicochemical properties and applications
Singh, M. P., Singh, R. K., & Chandra, S. (2014) · Progress in Materials Science · doi:10.1016/j.pmatsci.2014.03.001 · Cited by 318
Nanoporous Carbon Supercapacitors in an Ionic Liquid: A Computer Simulation Study
Shim, Y., & Kim, H. J. (2010) · ACS Nano · doi:10.1021/nn901916m · Cited by 292
Self-citation
Metadata
- Authors
- Shim, Y., & Kim, H. J.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-07-07
- Volume
- 3
- Issue
- 7
- Pages
- 1693-1702
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2085730658
- Cited by
- 160
- References
- 2
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.