The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Label-Free Porous Alumina Interferometric Immunosensor
Abstract
Anodization of Al is used to produce optically smooth porous alumina (Al(2)O(3)) films with pores approximately 60 nm in diameter and approximately 6 mum deep. The capture protein, protein A, is adsorbed to the pore walls by noncovalent, electrostatic interactions, and thin film interference spectroscopy is used to detect binding of immunoglobulin (IgG). The porous alumina films are stable against corrosion and dissolution in aqueous media at pH 7, allowing quantitative monitoring of steady-state and time-resolved biomolecular binding. The bare porous Al(2)O(3) surface displays a significantly greater affinity for protein A than for IgG. The known species specificity of protein A binding to IgG is confirmed; the protein-A-modified sensor responds to IgG derived from rabbit, but not chicken (IgG/IgY). A "cascaded", or multiprobe sensing approach, is demonstrated, in which a specific target, sheep IgG, is administered to a sample modified with a protein A/rabbit anti-sheep IgG assembly. Binding measurements are confirmed by fluorescence microscopy using fluorescein-labeled IgG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Cited by
Nanoporous anodic aluminium oxide: Advances in surface engineering and emerging applications
Md Jani, A. M., Losic, D., & Voelcker, N. H. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.01.002 · Cited by 553
Review article: Fabrication of nanofluidic devices
Duan, C., Wang, W., & Xie, Q. (2013) · Biomicrofluidics · doi:10.1063/1.4794973 · Cited by 274
Nanoporous anodic aluminum oxide for chemical sensing and biosensors
Santos, A., Kumeria, T., & Losic, D. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2012.11.007 · Cited by 253
Metadata
- Authors
- Alvarez, S. D., Li, C.-P., Chiang, C. E., Schuller, I. K., & Sailor, M. J.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-08-31
- Volume
- 3
- Issue
- 10
- Pages
- 3301-3307
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2075683716
- Cited by
- 158
- References
- 1
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.