Benzimidazole-Based Tripodal Receptor: Highly Selective Fluorescent Chemosensor for Iodide in Aqueous Solution
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
We synthesized a novel tripodal fluorescent receptor bearing benzimidazole motifs as recognition sites in the pods of the receptor. The recognition behavior of the receptor toward various anions was evaluated in CH3CN/H2O (9:1, v/v) solution. The receptor showed changes in fluorescent intensity only with I-, but it showed no significant changes on addition of other anions such as F-, Cl-, Br-, HSO4-, NO3-, CH3COO-, and H2PO4-.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Spectrophotometric Investigation of the Interaction of Iodine with Aromatic Hydrocarbons
Benesi, H. A., & Hildebrand, J. H. (1949) · Journal of the American Chemical Society · doi:10.1021/ja01176a030 · Cited by 8,004
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Fluorogenic and Chromogenic Chemosensors and Reagents for Anions
Martínez-Máñez, R., & Sancenón, F. (2003) · Chemical Reviews · doi:10.1021/cr010421e · Cited by 3,076
Gunnlaugsson, T., Glynn, M., Tocci (née Hussey), G. M., Kruger, P. E., & Pfeffer, F. M. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.08.017 · Cited by 1,257
Imidazolium receptors for the recognition of anions
Yoon, J., Kim, S. K., Singh, N. J., & Kim, K. S. (2006) · Chemical Society Reviews · doi:10.1039/b513733k · Cited by 798
Self-citationAlfred Werner Revisited: The Coordination Chemistry of Anions
Bowman-James, K. (2005) · Accounts of Chemical Research · doi:10.1021/ar040071t · Cited by 706
Chemosensors of Ion and Molecule Recognition
(1997) · Springer eBooks · doi:10.1007/978-94-011-3973-1 · Cited by 488
Receptors for tetrahedral oxyanions
Katayev, E. A., Ustynyuk, Y. A., & Sessler, J. L. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.04.013 · Cited by 472
Nonlinear fluorescence quenching and the origin of positive curvature in Stern-Volmer plots
Keizer, J. (1983) · Journal of the American Chemical Society · doi:10.1021/ja00344a013 · Cited by 335
Reflections on the construction of anion receptors
Schmidtchen, F. P. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.07.009 · Cited by 197
Haldimann, M., Zimmerli, B., Als, C., & Gerber, H. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.4.817 · Cited by 153
Spin trapping of peroxy radicals by phenyl N-(tert-butyl) nitrone and methyl N-duryl nitrone
Niki, E., Yokoi, S., Tsuchiya, J., & Kamiya, Y. (1983) · Journal of the American Chemical Society · doi:10.1021/ja00344a014 · Cited by 81
Cited by
Chromogenic/Fluorogenic Ensemble Chemosensing Systems
Wu, J., Kwon, B., Liu, W., Anslyn, E. V., Wang, P., & Kim, J. S. (2015) · Chemical Reviews · doi:10.1021/cr500553d · Cited by 402
Colorimetric Recognition of Anions Using Preorganized Tetra-Amidourea Derived Calix[4]arene Sensors
Quinlan, E., Matthews, S. E., & Gunnlaugsson, T. (2007) · The Journal of Organic Chemistry · doi:10.1021/jo070439a · Cited by 201
Kim, Y., Kumar, M. R., Park, N., Heo, Y., & Lee, S. (2011) · The Journal of Organic Chemistry · doi:10.1021/jo2019416 · Cited by 182
Carbon dots-based fluorescent probes for sensitive and selective detection of iodide
Du, F., Zeng, F., Ming, Y., & Wu, S. (2013) · Microchimica Acta · doi:10.1007/s00604-013-0954-2 · Cited by 181
“In addition, elemental iodine is used in synthesizing some organic chemicals, in manufacturing dyes, in medicine, in analytical chemistry, and in other applications [3].”
BackgroundFully Conjugated [4]Chrysaorene. Redox-Coupled Anion Binding in a Tetraradicaloid Macrocycle
Gregolińska, H., Majewski, M., Chmielewski, P. J., Gregoliński, J., Chien, A., Zhou, J., Wu, Y.-L., Bae, Y. J., Wasielewski, M. R., Zimmerman, P. M., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b09385 · Cited by 54
Metadata
- Authors
- Singh, N., & Jang, D. O.
- Venue
- Organic Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-04-18
- Volume
- 9
- Issue
- 10
- Pages
- 1991-1994
- ISSN
- 1523-7052 (ISSN-L)
- 1523-7060
- OpenAlex
- W2004432066
- Cited by
- 242
- References
- 12
- FWCI
- 6.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.