The DOI matches its Crossref record.
Highly Sensitive and Selective Chemosensor for Hg2+ Based on the Rhodamine Fluorophore
Abstract
A novel tren-based tripodal chemosensor 1 bearing a rhodamine and two tosyl groups was synthesized and its sensing behavior toward metal ions was investigated by UV/vis and fluorescence spectroscopies. Addition of a Hg2+ ion to a CH3CN solution of 1 gave a visual color change as well as significantly enhanced fluorescence, while other ions including Pb2+, Zn2+, Cu2+, Ca2+, Ba2+, Cd2+, Co2+, Mg2+, Ag+, Cs+, Li+, and Na+ induced no or much smaller color/spectral changes, which constituted a Hg2+-selective fluorescent chemosensor (OFF-ON).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A new trend in rhodamine-based chemosensors: application of spirolactam ring-opening to sensing ions
Kim, H. N., Lee, M. H., Kim, H. J., Kim, J. S., & Yoon, J. (2008) · Chemical Society Reviews · doi:10.1039/b802497a · Cited by 1,649
Self-citationRatiometric Detection of Cr3+and Hg2+by a Naphthalimide-Rhodamine Based Fluorescent Probe
Mahato, P., Saha, S., Suresh, E., Di Liddo, R., Parnigotto, P. P., Conconi, M. T., Kesharwani, M. K., Ganguly, B., & Das, A. (2012) · Inorganic Chemistry · doi:10.1021/ic202073q · Cited by 319
Liu, M., Wang, Z., Zong, S., Chen, H., Zhu, D., Wu, L., Hu, G., & Cui, Y. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am5006282 · Cited by 178
Metadata
- Authors
- Lee, M. H., Wu, J.-S., Lee, J. W., Jung, J. H., & Kim, J. S.
- Venue
- Organic Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-05-26
- Volume
- 9
- Issue
- 13
- Pages
- 2501-2504
- ISSN
- 1523-7052 (ISSN-L)
- 1523-7060
- OpenAlex
- W2053012775
- Cited by
- 317
- References
- 0
- FWCI
- 14.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive and Selective Chemosensor for Hg2+ Based on the Rhodamine Fluorophore. https://app.cochat.ai/papers/10.1021/ol0708931
- The paper
- Lee, M. H., Wu, J.-S., Lee, J. W., Jung, J. H., & Kim, J. S. (2007). Highly Sensitive and Selective Chemosensor for Hg2+ Based on the Rhodamine Fluorophore. Organic Letters. https://doi.org/10.1021/ol0708931
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.