The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Reaction-Based Sensing of Fluoride Ions Using Built-In Triggers for Intramolecular Charge Transfer and Photoinduced Electron Transfer
Open accessAbstract
Two Bodipy derivatives with silyl-protected phenolic functionalities signal fluoride concentrations both in solution and in a poly(methyl methacrylate) matrix. The exact location of the "nascent" phenolate group is important. If it is at the meso position, photoinduced electron transfer is triggered; however, if it is in full conjugation via a styryl moiety to the Bodipy core, strong intramolecular charge transfer is triggered, resulting in a large red shift in the absorbance peak. In either case, a selective methodology for fluoride sensing is the invariable result.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BODIPY Dyes and Their Derivatives: Syntheses and Spectroscopic Properties
Loudet, A., & Burgess, K. (2007) · Chemical Reviews · doi:10.1021/cr078381n · Cited by 5,238
Cited by
Fluorescent indicators based on BODIPY
Boens, N., Leen, V., & Dehaen, W. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15132k · Cited by 2,262
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Triplet photosensitizers: from molecular design to applications
Zhao, J., Wu, W., Sun, J., & Guo, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35531d · Cited by 1,579
Fluorescence and Colorimetric Chemosensors for Fluoride-Ion Detection
Zhou, Y., Zhang, J. F., & Yoon, J. (2014) · Chemical Reviews · doi:10.1021/cr400352m · Cited by 1,072
Du, J., Hu, M., Fan, J., & Peng, X. (2012) · Chemical Society Reviews · doi:10.1039/c2cs00004k · Cited by 688
Metadata
- Authors
- Bozdemir, O. A., Sozmen, F., Buyukcakir, O., Guliyev, R., Cakmak, Y., & Akkaya, E. U.
- Venue
- Organic Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-03-11
- Volume
- 12
- Issue
- 7
- Pages
- 1400-1403
- ISSN
- 1523-7052 (ISSN-L)
- 1523-7060
- OpenAlex
- W2071876405
- Cited by
- 196
- References
- 1
- FWCI
- 10.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.