The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Hg2+-Selective Ratiometric and “Off−On” Chemosensor Based on the Azadiene−Pyrene Derivative
Abstract
A new pyrene-based derivative bearing an azadiene group was synthesized as a ratiometric chemosensor for Hg(2+) in aqueous acetonitrile solution. The "off-on" type signaling behavior of the fluoroionophore is due to the metal ion induced conformational changes from the weak pyrene monomer emissions to strong pyrene excimer emission.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The toxicology of mercury—current exposures and clinical manifestations
Clarkson, T. W., Magos, L., & Myers, G. J. (2003) · New England Journal of Medicine · doi:10.1056/nejmra022471 · Cited by 1,766
Cited by
Metal coordination in photoluminescent sensing
Liu, Z., He, W., & Guo, Z. (2013) · Chemical Society Reviews · doi:10.1039/c2cs35363f · Cited by 800
Metadata
- Authors
- Zhou, Y., Zhu, C.-Y., Gao, X.-S., You, X.-Y., & Yao, C.
- Venue
- Organic Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-05-07
- Volume
- 12
- Issue
- 11
- Pages
- 2566-2569
- ISSN
- 1523-7052 (ISSN-L)
- 1523-7060
- OpenAlex
- W2047830986
- Cited by
- 185
- References
- 1
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hg2+-Selective Ratiometric and “Off−On” Chemosensor Based on the Azadiene−Pyrene Derivative. https://app.cochat.ai/papers/10.1021/ol1007636
- The paper
- Zhou, Y., Zhu, C.-Y., Gao, X.-S., You, X.-Y., & Yao, C. (2010). Hg2+-Selective Ratiometric and “Off−On” Chemosensor Based on the Azadiene−Pyrene Derivative. Organic Letters. https://doi.org/10.1021/ol1007636
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.