The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ratiometric Sensing of Fluoride Anions Based on a BODIPY-Coumarin Platform
Abstract
Based on a new coumarin-BODIPY platform, compound 4 was rationally designed and synthesized as a novel ratiometric fluorescent sensor for fluoride anions. The sensor exhibited a large red shift (88 nm) in absorption and a drastic ratiometric fluorescent response (I(472)/I(606) = 17.4) to fluoride anions. Density function theory and time-dependent density function theory calculations were conducted to rationalize the optical response of the sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BODIPY Dyes and Their Derivatives: Syntheses and Spectroscopic Properties
Loudet, A., & Burgess, K. (2007) · Chemical Reviews · doi:10.1021/cr078381n · Cited by 5,238
Cited by
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Applications of Supramolecular Anion Recognition
Busschaert, N., Caltagirone, C., Van Rossom, W., & Gale, P. A. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00099 · Cited by 1,249
Fluorescence and Colorimetric Chemosensors for Fluoride-Ion Detection
Zhou, Y., Zhang, J. F., & Yoon, J. (2014) · Chemical Reviews · doi:10.1021/cr400352m · Cited by 1,072
Santos-Figueroa, L. E., Moragues, M. E., Climent, E., Agostini, A., Martínez-Máñez, R., & Sancenón, F. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35429f · Cited by 594
Metadata
- Authors
- Cao, X., Lin, W., Yu, Q., & Wang, J.
- Venue
- Organic Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-10-27
- Volume
- 13
- Issue
- 22
- Pages
- 6098-6101
- ISSN
- 1523-7052 (ISSN-L)
- 1523-7060
- OpenAlex
- W2313619626
- Cited by
- 178
- References
- 1
- FWCI
- 9.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.