Dimeric Aluminum Chloride Complexes of N-Alkoxyalkyl-β-ketoimines: Activation with Propylene Oxide To Form Efficient Lactide Polymerization Catalysts
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The ter- and tetradentate N -alkoxyalkyl-β-ketoimines CH 3 C(O)CH 2 C(NCH 2 CHROH)CH 3 { L 1 - 3 } react with diethylaluminum chloride to afford the dimeric chloride bridged complexes [{ L 1 - 3 }AlCl] 2 ( 1a − c ), which are activated by addition of propylene oxide or cyclohexene oxide to afford efficient initiators for the ring-opening polymerization of ( d, l )-lactide. The active species is believed to be a chloroalkoxide formed by nucleophilic ring opening of a coordinated PO by migration of the chloride coordinated to the adjacent aluminum center. The resulting polymers have a high molecular weight, close to that calculated for the monomer:initiator ratio of 100, and a narrow molecular weight distribution. While the corresponding aluminum methyl dimer [{ L 1 }AlMe] 2 ( 2a ), formed by reaction of L 1 (R = H) with AlMe 3, is a poor inititaor for the polymeriation of ( d, l )-lactide, addition of 2-chloroethanol affords a catalyst with an activity comparable to that of 1a /PO. The molecular weight and molecular weight distribution of the resulting polylactide is similar to that obtained with 1a /PO and consistent with formation of a similar chloroalkoxide initiator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ovitt, T. M., & Coates, G. W. (2002) · Journal of the American Chemical Society · doi:10.1021/ja012052+ · Cited by 713
Ovitt, T. M., & Coates, G. W. (1999) · Journal of the American Chemical Society · doi:10.1021/ja990088k · Cited by 502
Radano, C. P., Baker, G. L., & Smith, M. R. (2000) · Journal of the American Chemical Society · doi:10.1021/ja9930519 · Cited by 403
Cited by
New emerging trends in synthetic biodegradable polymers—Polylactide: A critique
Gupta, A. P., & Kumar, V. (2007) · European Polymer Journal · doi:10.1016/j.eurpolymj.2007.06.045 · Cited by 941
WU, J., YU, T., CHEN, C., & LIN, C. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2005.07.010 · Cited by 779
Biocompatible Initiators for Lactide Polymerization
Platel, R., Hodgson, L., & Williams, C. (2008) · Polymer Reviews · doi:10.1080/15583720701834166 · Cited by 706
Synthesis of Poly(Lactic Acid): A Review
Mehta, R., Kumar, V., Bhunia, H., & Upadhyay, S. N. (2005) · Journal of Macromolecular Science, Part C: Polymer Reviews · doi:10.1080/15321790500304148 · Cited by 510
Chen, H.-Y., Tang, H.-Y., & Lin, C.-C. (2006) · Macromolecules · doi:10.1021/ma060471r · Cited by 270
Metadata
- Authors
- Doherty, S., Errington, R. J., Housley, N., & Clegg, W.
- Venue
- Organometallics
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-03-23
- Volume
- 23
- Issue
- 10
- Pages
- 2382-2388
- ISSN
- 0276-7333 (ISSN-L)
- 1520-6041
- OpenAlex
- W2072978368
- Cited by
- 75
- References
- 3
- FWCI
- 1.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.