Evaluation of a Cleavable Stable Isotope Labeled Synthetic Peptide for Absolute Protein Quantification Using LC−MS/MS
The DOI matches its Crossref record.
Abstract
Protein cleavage coupled with isotope dilution mass spectrometry (PC-IDMS) has the potential to provide the absolute concentration of a specific protein, or multiple proteins, in complex mixtures. However, PC-IDMS differs from standard IDMS since the internal standard is a different molecule than the analyte at the start of the experiment, more specifically, the internal standard is a peptide and the analyte is a protein prior to cleavage. It is not until after the cleavage process that the stable isotope labeled synthetic peptide has the same physicochemical behavior as the peptide cleaved from the protein. The work presented here evaluates the use of tryptic cleavage sites incorporated into the internal standard synthetic peptide in an attempt to create an internal standard that has cleavage characteristics more similar to the protein being quantified. Results presented here suggest that an internal standard synthetic peptide incorporating internal cleavage sites does not improve the accuracy and precision of the values obtained when performing PC-IDMS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cheng, D., Hoogenraad, C. C., Rush, J., Ramm, E., Schlager, M. A., Duong, D. M., Xu, P., Wijayawardana, S. R., Hanfelt, J., Nakagawa, T., et al. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.d500009-mcp200 · Cited by 510
“As the AQUA strategy requires complete digestion of target proteins that is often affected by the selection of digestion conditions (50, 51), we used the extremely stable protein ubiquitin to optimize digestion conditions and found that all tryptic sites except one flanked by two acidic residues in ubiquitin could be…”
MethodQuantitative phosphoproteomics by mass spectrometry: Past, present, and future
Nita‐Lazar, A., Saito‐Benz, H., & White, F. M. (2008) · PROTEOMICS · doi:10.1002/pmic.200800231 · Cited by 162
“Typically, absolute quantification would have required the chemical synthesis of heavy-isotope coded peptides [35] to be added to the sample as internal standards.”
Quantifying Protein Measurands by Peptide Measurements: Where Do Errors Arise?
van den Broek, I., Romijn, F. P. H. T. M., Smit, N. P. M., van der Laarse, A., Drijfhout, J. W., van der Burgt, Y. E. M., & Cobbaert, C. M. (2015) · Journal of Proteome Research · doi:10.1021/pr5011179 · Cited by 49
van den Broek, I., Smit, N. P. M., Romijn, F. P. H. T. M., van der Laarse, A., Deelder, A. M., van der Burgt, Y. E. M., & Cobbaert, C. M. (2013) · Journal of Proteome Research · doi:10.1021/pr400763d · Cited by 49
Metadata
- Authors
- Barnidge, D. R., Hall, G. D., Stocker, J. L., & Muddiman, D. C.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-03-02
- Volume
- 3
- Issue
- 3
- Pages
- 658-661
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W2026394337
- Cited by
- 89
- References
- 0
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of a Cleavable Stable Isotope Labeled Synthetic Peptide for Absolute Protein Quantification Using LC−MS/MS. https://app.cochat.ai/papers/10.1021/pr034124x
- The paper
- Barnidge, D. R., Hall, G. D., Stocker, J. L., & Muddiman, D. C. (2004). Evaluation of a Cleavable Stable Isotope Labeled Synthetic Peptide for Absolute Protein Quantification Using LC−MS/MS. Journal of Proteome Research. https://doi.org/10.1021/pr034124x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.