The Proteomic Reactor: A Microfluidic Device for Processing Minute Amounts of Protein Prior to Mass Spectrometry Analysis
The DOI matches its Crossref record.
Abstract
Gel-free proteomics has emerged as a complement to conventional gel-based proteomics. Gel-free approaches focus on peptide or protein fractionation, but they do not address the efficiency of protein processing. We report the development of a microfluidic proteomic reactor that greatly simplifies the processing of complex proteomic samples by combining multiple proteomic steps. Rapid extraction and enrichment of proteins from complex proteomic samples or directly from cells are readily performed on the reactor. Furthermore, chemical and enzymatic treatments of proteins are performed in 50 nL effective volume, which results in an increased number of generated peptides. The products are compatible with mass spectrometry. We demonstrated that the proteomic reactor is at least 10 times more sensitive than current gel-free methodologies with one protein identified per 440 pg of protein lysate injected on the reactor. Furthermore, as little as 300 cells can be directly introduced on the proteomic reactor and analyzed by mass spectrometry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Single-pot, solid-phase-enhanced sample preparation for proteomics experiments
Hughes, C. S., Moggridge, S., Müller, T., Sorensen, P. H., Morin, G. B., & Krijgsveld, J. (2019) · Nature Protocols · doi:10.1038/s41596-018-0082-x · Cited by 1,941
Kulak, N. A., Pichler, G., Paron, I., Nagaraj, N., & Mann, M. (2014) · Nature Methods · doi:10.1038/nmeth.2834 · Cited by 1,719
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Ultrasensitive proteome analysis using paramagnetic bead technology
Hughes, C. S., Foehr, S., Garfield, D. A., Furlong, E. E., Steinmetz, L. M., & Krijgsveld, J. (2014) · Molecular Systems Biology · doi:10.15252/msb.20145625 · Cited by 1,225
Wiśniewski, J. R., & Mann, M. (2012) · Analytical Chemistry · doi:10.1021/ac300006b · Cited by 299
Metadata
- Authors
- Ethier, M., Hou, W., Duewel, H. S., & Figeys, D.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-08-22
- Volume
- 5
- Issue
- 10
- Pages
- 2754-2759
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W2000146915
- Cited by
- 86
- References
- 0
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Proteomic Reactor: A Microfluidic Device for Processing Minute Amounts of Protein Prior to Mass Spectrometry Analysis. https://app.cochat.ai/papers/10.1021/pr060312m
- The paper
- Ethier, M., Hou, W., Duewel, H. S., & Figeys, D. (2006). The Proteomic Reactor: A Microfluidic Device for Processing Minute Amounts of Protein Prior to Mass Spectrometry Analysis. Journal of Proteome Research. https://doi.org/10.1021/pr060312m
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.