Improving SRM Assay Development: A Global Comparison between Triple Quadrupole, Ion Trap, and Higher Energy CID Peptide Fragmentation Spectra
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
In proteomics, selected reaction monitoring (SRM) is rapidly gaining importance for targeted protein quantification. The triple quadrupole mass analyzers used in SRM assays allow for levels of specificity and sensitivity hard to accomplish by more standard shotgun proteomics experiments. Often, an SRM assay is built by in silico prediction of transitions and/or extraction of peptide precursor and fragment ions from a spectral library. Spectral libraries are typically generated from nonideal ion trap based shotgun proteomics experiments or synthetic peptide libraries, consuming considerable time and effort. Here, we investigate the usability of beam type CID (or "higher energy CID" (HCD)) peptide fragmentation spectra, as acquired using an Orbitrap Velos, to facilitate SRM assay development. Therefore, peptide fragmentation spectra, obtained by ion-trap CID, triple-quadrupole CID (QqQ-CID) and Orbitrap HCD, originating from digested cellular lysates, were compared. Spectral comparison and a dedicated correlation algorithm indicated significantly higher similarity between QqQ-CID and HCD fragmentation spectra than between QqQ-CID and ion trap-CID spectra. SRM transitions generated using a constructed HCD spectral library increased SRM assay sensitivity up to 2-fold, when compared to the use of a library created from more conventionally used ion trap-CID spectra, showing that HCD spectra can assist SRM assay development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Skyline: an open source document editor for creating and analyzing targeted proteomics experiments
MacLean, B., Tomazela, D. M., Shulman, N., Chambers, M., Finney, G. L., Frewen, B., Kern, R., Tabb, D. L., Liebler, D. C., & MacCoss, M. J. (2010) · Bioinformatics · doi:10.1093/bioinformatics/btq054 · Cited by 4,697
Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832254100 · Cited by 1,733
Desiere, F. (2006) · Nucleic Acids Research · doi:10.1093/nar/gkj040 · Cited by 910
Full dynamic range proteome analysis of S. cerevisiae by targeted proteomics
Picotti, P., Bodenmiller, B., Mueller, L. N., Domon, B., & Aebersold, R. (2009) · Cell · doi:10.1016/j.cell.2009.05.051 · Cited by 744
A dual pressure linear ion trap orbitrap instrument with very high sequencing speed
Olsen, J. V., Schwartz, J. C., Griep-Raming, J., Nielsen, M. L., Damoc, E., Denisov, E., Lange, O., Remes, P., Taylor, D., Splendore, M., et al. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900375-mcp200 · Cited by 464
Prakash, A., Tomazela, D. M., Frewen, B., MacLean, B., Merrihew, G., Peterman, S., & MacCoss, M. J. (2009) · Journal of Proteome Research · doi:10.1021/pr801028b · Cited by 147
Cited by
Data‐independent acquisition‐based SWATH ‐ MS for quantitative proteomics: a tutorial
Ludwig, C., Gillet, L., Rosenberger, G., Amon, S., Collins, B. C., & Aebersold, R. (2018) · Molecular Systems Biology · doi:10.15252/msb.20178126 · Cited by 1,002
A repository of assays to quantify 10,000 human proteins by SWATH-MS
Rosenberger, G., Koh, C. C., Guo, T., Röst, H. L., Kouvonen, P., Collins, B. C., Heusel, M., Liu, Y., Caron, E., Vichalkovski, A., et al. (2014) · Scientific Data · doi:10.1038/sdata.2014.31 · Cited by 413
Targeted Quantitation of Proteins by Mass Spectrometry
Liebler, D. C., & Zimmerman, L. J. (2013) · Biochemistry · doi:10.1021/bi400110b · Cited by 363
Building high-quality assay libraries for targeted analysis of SWATH MS data
Schubert, O. T., Gillet, L. C., Collins, B. C., Navarro, P., Rosenberger, G., Wolski, W. E., Lam, H., Amodei, D., Mallick, P., MacLean, B., et al. (2015) · Nature Protocols · doi:10.1038/nprot.2015.015 · Cited by 309
Frese, C. K., Altelaar, A. F. M., van den Toorn, H., Nolting, D., Griep-Raming, J., Heck, A. J. R., & Mohammed, S. (2012) · Analytical Chemistry · doi:10.1021/ac3025366 · Cited by 304
Self-citationAnalysis of High Accuracy, Quantitative Proteomics Data in the MaxQB Database
Schaab, C., Geiger, T., Stoehr, G., Cox, J., & Mann, M. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.014068 · Cited by 164
“…of us-ing MaxQB for this use case is the fact that this database contains high resolution fragmentation spectra that are obtained by the higher energy collisional dissociation method, which produces very similar transitions to those that would be observed in triple quadrupole methods (30).”
MethodXiong, Q., Feng, J., Li, S.-T., Zhang, G.-Y., Qiao, Z.-X., Chen, Z., Wu, Y., Lin, Y., Li, T., Ge, F., et al. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.046003 · Cited by 64
“Strong Cation Exchange Fractionation—Peptides were fractionated using strong-cation exchange as described previously (28).”
Method
Metadata
- Authors
- de Graaf, E. L., Altelaar, A. F. M., van Breukelen, B., Mohammed, S., & Heck, A. J. R.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-07-21
- Volume
- 10
- Issue
- 9
- Pages
- 4334-4341
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W2115927224
- Cited by
- 93
- References
- 6
- FWCI
- 4.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.