Effects of Traveling Wave Ion Mobility Separation on Data Independent Acquisition in Proteomics Studies
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
qTOF mass spectrometry and traveling wave ion mobility separation (TWIMS) hybrid instruments (q-TWIMS-TOF) have recently become commercially available. Ion mobility separation allows an additional dimension of precursor separation inside the instrument, without incurring an increase in instrument time. We comprehensively investigated the effects of TWIMS on data-independent acquisition on a Synapt G2 instrument. We observed that if fragmentation is performed post TWIMS, more accurate assignment of fragment ions to precursors is possible in data independent acquisition. This allows up to 60% higher proteome coverage and higher confidence of protein and peptide identifications. Moreover, the majority of peptides and proteins identified upon application of TWIMS span the lower intensity range of the proteome. It has also been demonstrated in several studies that employing IMS results in higher peak capacity of separation and consequently more accurate and precise quantitation of lower intensity precursor ions. We observe that employing TWIMS results in an attenuation of the detected ion current. We postulate that this effect is binary; sensitivity is reduced due to ion scattering during transfer into a high pressure "IMS zone", sensitivity is reduced due to the saturation of detector digitizer as a result of the IMS concentration effect. This latter effect limits the useful linear range of quantitation, compromising quantitation accuracy of high intensity peptides. We demonstrate that the signal loss from detector saturation and transmission loss can be deconvoluted by investigation of the peptide isotopic envelope. We discuss the origin and extent of signal loss and suggest methods to minimize these effects on q-TWIMS-TOF instrument in the light of different experimental designs and other IMS/MS platforms described previously.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global analysis of protein expression in yeast
Ghaemmaghami, S., Huh, W.-K., Bower, K., Howson, R. W., Belle, A., Dephoure, N., O'Shea, E. K., & Weissman, J. S. (2003) · Nature · doi:10.1038/nature02046 · Cited by 3,750
Gillet, L. C., Navarro, P., Tate, S., Röst, H., Selevsek, N., Reiter, L., Bonner, R., & Aebersold, R. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.016717 · Cited by 2,877
Absolute Quantification of Proteins by LCMSE
Silva, J. C., Gorenstein, M. V., Li, G.-Z., Vissers, J. P. C., & Geromanos, S. J. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500230-mcp200 · Cited by 1,529
Michalski, A., Cox, J., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr101060v · Cited by 685
Cited by
Lanucara, F., Holman, S. W., Gray, C. J., & Eyers, C. E. (2014) · Nature Chemistry · doi:10.1038/nchem.1889 · Cited by 901
A flavin-based extracellular electron transfer mechanism in diverse Gram-positive bacteria
Light, S. H., Su, L., Rivera-Lugo, R., Cornejo, J. A., Louie, A., Iavarone, A. T., Ajo-Franklin, C. M., & Portnoy, D. A. (2018) · Nature · doi:10.1038/s41586-018-0498-z · Cited by 632
Ion Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
May, J. C., & McLean, J. A. (2015) · Analytical Chemistry · doi:10.1021/ac504720m · Cited by 435
Meier, F., Beck, S., Grassl, N., Lubeck, M., Park, M. A., Raether, O., & Mann, M. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00932 · Cited by 423
Label-free quantification in ion mobility–enhanced data-independent acquisition proteomics
Distler, U., Kuharev, J., Navarro, P., & Tenzer, S. (2016) · Nature Protocols · doi:10.1038/nprot.2016.042 · Cited by 329
James, E. I., Murphree, T. A., Vorauer, C., Engen, J. R., & Guttman, M. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00279 · Cited by 305
Dietary- and host-derived metabolites are used by diverse gut bacteria for anaerobic respiration
Little, A. S., Younker, I. T., Schechter, M. S., Bernardino, P. N., Méheust, R., Stemczynski, J., Scorza, K., Mullowney, M. W., Sharan, D., Waligurski, E., et al. (2024) · Nature Microbiology · doi:10.1038/s41564-023-01560-2 · Cited by 80
Distinct gene clusters drive formation of ferrosome organelles in bacteria
Grant, C. R., Amor, M., Trujillo, H. A., Krishnapura, S., Iavarone, A. T., & Komeili, A. (2022) · Nature · doi:10.1038/s41586-022-04741-x · Cited by 45
Metadata
- Authors
- Shliaha, P. V., Bond, N. J., Gatto, L., & Lilley, K. S.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-05-02
- Volume
- 12
- Issue
- 6
- Pages
- 2323-2339
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W1978065328
- Cited by
- 101
- References
- 4
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.