MS1-Based Label-Free Proteomics Using a Quadrupole Orbitrap Mass Spectrometer
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Presented is a data set for benchmarking MS1-based label-free quantitative proteomics using a quadrupole orbitrap mass spectrometer. Escherichia coli digest was spiked into a HeLa digest in four different concentrations, simulating protein expression differences in a background of an unchanged complex proteome. The data set provides a unique opportunity to evaluate the proteomic platform (instrumentation and software) in its ability to perform MS1-intensity-based label-free quantification. We show that the presented combination of informatics and instrumentation produces high precision and quantification accuracy. The data were also used to compare different quantitative protein inference methods such as iBAQ and Hi-N. The data can also be used as a resource for development and optimization of proteomics informatics tools, thus the raw data have been deposited to ProteomeXchange with identifier PXD001385.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cox, J., Hein, M. Y., Luber, C. A., Paron, I., Nagaraj, N., & Mann, M. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.031591 · Cited by 5,180
Ross, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401
Absolute Quantification of Proteins by LCMSE
Silva, J. C., Gorenstein, M. V., Li, G.-Z., Vissers, J. P. C., & Geromanos, S. J. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500230-mcp200 · Cited by 1,529
Lu, P., Vogel, C., Wang, R., Yao, X., & Marcotte, E. M. (2007) · Nature Biotechnology · doi:10.1038/nbt1270 · Cited by 1,139
Deep proteome and transcriptome mapping of a human cancer cell line
Nagaraj, N., Wisniewski, J. R., Geiger, T., Cox, J., Kircher, M., Kelso, J., Pääbo, S., & Mann, M. (2011) · Molecular Systems Biology · doi:10.1038/msb.2011.81 · Cited by 979
Quantitative, High-Resolution Proteomics for Data-Driven Systems Biology
Cox, J., & Mann, M. (2011) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-061308-093216 · Cited by 685
Collins, B. C., Gillet, L. C., Rosenberger, G., Röst, H. L., Vichalkovski, A., Gstaiger, M., & Aebersold, R. (2013) · Nature Methods · doi:10.1038/nmeth.2703 · Cited by 314
Cited by
Integrated omics: tools, advances and future approaches
Misra, B. B., Langefeld, C., Olivier, M., & Cox, L. A. (2019) · Journal of Molecular Endocrinology · doi:10.1530/jme-18-0055 · Cited by 686
Yoon, S., Kovalenko, A., Bogdanov, K., & Wallach, D. (2017) · Immunity · doi:10.1016/j.immuni.2017.06.001 · Cited by 368
Mor, N., Rais, Y., Sheban, D., Peles, S., Aguilera-Castrejon, A., Zviran, A., Elinger, D., Viukov, S., Geula, S., Krupalnik, V., et al. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.07.004 · Cited by 79
Self-citationTriple-Stage Mass Spectrometry Unravels the Heterogeneity of an Endogenous Protein Complex
Ben-Nissan, G., Belov, M. E., Morgenstern, D., Levin, Y., Dym, O., Arkind, G., Lipson, C., Makarov, A. A., & Sharon, M. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00518 · Cited by 54
Self-citationSánchez, B. J., Lahtvee, P., Campbell, K., Kasvandik, S., Yu, R., Domenzain, I., Zelezniak, A., & Nielsen, J. (2021) · PROTEOMICS · doi:10.1002/pmic.202000093 · Cited by 18
Metadata
- Authors
- Shalit, T., Elinger, D., Savidor, A., Gabashvili, A., & Levin, Y.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-03-24
- Volume
- 14
- Issue
- 4
- Pages
- 1979-1986
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W2320840592
- Cited by
- 85
- References
- 7
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.