Immobilized Metal Affinity Chromatography Revisited: pH/Acid Control toward High Selectivity in Phosphoproteomics
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Despite recent advances in instrumentation and analytical strategies for identification and quantitation of protein phosphorylation, a highly specific enrichment protocol is still a challenge in large-scale studies. Here, we report a simple pH/acid control method that addresses the poor specificity seriously criticized in IMAC. Detailed evaluation of the capture and release mechanism in IMAC revealed that pH, buffer and salt yield a complex interplay in enrichment of phosphopeptides, yet they play individual roles in recovery and specificity. A revised one-step IMAC method with low sample loss and high specificity can be rationally designed by controlling salt, pH and the structure and concentration of organic acid. Without methyl esterification, the one-step IMAC enrichment with single LC-MS/MS identified 386 phosphoproteins in 550 mug of non-small-cell lung cancer cell lysate with 96% specificity. Additional fractionation by SDS-PAGE from 4 mg of cell lysate revealed the comprehensive proteome map, identifying 2747 phosphorylation sites from 2360 nondegenerate phosphopeptides and 1219 phosphoproteins with a false discovery rate of 0.63%. To our knowledge, this pH/acid-controlled IMAC procedure provides higher specificity than any other one-step IMAC purification procedure. Furthermore, the simple and reproducible IMAC protocol can be adapted to other solid supports, fully automated or manual, for large-scale identification of the vastly under-explored phosphoproteome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Large-scale phosphorylation analysis of mouse liver
Villén, J., Beausoleil, S. A., Gerber, S. A., & Gygi, S. P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609836104 · Cited by 730
Cited by
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
“The IMAC selectivity and specificity can be altered with different buffer conditions, such as pH, salt concentration (112), buffer composition, and the presence of detergents (113).”
BackgroundHuman Protein Reference Database and Human Proteinpedia as resources for phosphoproteome analysis
Goel, R., Harsha, H. C., Pandey, A., & Prasad, T. S. K. (2011) · Molecular BioSystems · doi:10.1039/c1mb05340j · Cited by 211
Enrichment techniques employed in phosphoproteomics
Fíla, J., & Honys, D. (2012) · Amino Acids · doi:10.1007/s00726-011-1111-z · Cited by 198
“between the specific antagonistic demands (Tsai et al. 2008).”
BackgroundMethodResultInfluentialThe nuclear envelope LEM-domain protein emerin
Berk, J. M., Tifft, K. E., & Wilson, K. L. (2013) · Nucleus · doi:10.4161/nucl.25751 · Cited by 186
Wang, Z.-G., Lv, N., Bi, W.-Z., Zhang, J.-L., & Ni, J.-Z. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b01254 · Cited by 158
Metadata
- Authors
- Tsai, C.-F., Wang, Y.-T., Chen, Y.-R., Lai, C.-Y., Lin, P.-Y., Pan, K.-T., Chen, J.-Y., Khoo, K.-H., & Chen, Y.-J.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-08-16
- Volume
- 7
- Issue
- 9
- Pages
- 4058-4069
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W1986977491
- Cited by
- 129
- References
- 1
- FWCI
- 6.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.