The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Dynamic Monitoring of Cytotoxicity on Microelectronic Sensors
Abstract
A real-time cell electronic sensing (RT-CES) system was used for label-free, dynamic measurement of cell responses to cytotoxicants. Cells were grown onto the surfaces of microelectronic sensors, which are comprised of circle-on-line electrode arrays and are integrated into the bottom surfaces of the microtiter plate. Changes in cell status such as cell number, viability, morphology, and adherence were monitored and quantified by detecting sensor electrical impedance. For cell quantification and viability measurement, the data generated on the RT-CES system correlated well with those from the colorimetric (MTT) assay. For cytotoxicity assessment, cells growing on microelectronic sensors were treated with different cytotoxicants, such as arsenic, mercury, and sodium dichromate. The dynamic responses of the cells to the toxicants were continuously monitored by the RT-CES system. On the basis of the IC50 values, the RT-CES system displays an equal sensitivity to the neutral red uptake assay at specific time points. Furthermore, because the RT-CES system provides real-time information regarding the state of cell morphology and adhesion in addition to cell number, we were able to discern a previously unreported effect of arsenic on NIH 3T3 cells prior to cell death. Also, using the RT-CES system, we were able to monitor cytotoxicity effects that occur within a minute of compound addition. Taken together, the RT-CES system allows for real-time, continuous monitoring and quantitative recording of the whole assay process and provides new insight into the cell-toxicant interaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular targeting therapy of cancer: drug resistance, apoptosis and survival signal
Tsuruo, T., Naito, M., Tomida, A., Fujita, N., Mashima, T., Sakamoto, H., & Haga, N. (2003) · Cancer Science · doi:10.1111/j.1349-7006.2003.tb01345.x · Cited by 502
Bagchi, D., Bagchi, M., & Stohs, S. J. (2001) · Molecular and Cellular Biochemistry · doi:10.1023/a:1017958028256 · Cited by 237
PREDICTIVE VALUE OF IN VITRO MODEL SYSTEMS IN TOXICOLOGY
Davila, J. C., Rodriguez, R. J., Melchert, R. B., & Acosta, D. (1998) · The Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev.pharmtox.38.1.63 · Cited by 131
New perspectives in arsenic-induced cell signal transduction
Qian, Y. R., Castranova, V., & Shi, X. (2003) · Journal of Inorganic Biochemistry · doi:10.1016/s0162-0134(03)00235-6 · Cited by 113
Advances in Cytochemical Methods for Detection of Apoptosis
Barrett, K. L., Willingham, J. M., Garvin, A. J., & Willingham, M. C. (2001) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215540104900703 · Cited by 84
Switching from life to death: The Miz-ing link between Myc and p53
Vousden, K. H. (2002) · Cancer Cell · doi:10.1016/s1535-6108(02)00186-1 · Cited by 56
Predictive drug allergy testing: an alternative viewpoint
Pichler, W. J. (2001) · Toxicology · doi:10.1016/s0300-483x(00)00399-1 · Cited by 38
Bagchi, D., Bagchi, M., & STOHS, S. J. (2001) · Springer eBooks · doi:10.1007/978-1-4615-0793-2_18 · Cited by 34
Cited by
The ToxCast Program for Prioritizing Toxicity Testing of Environmental Chemicals
Dix, D. J., Houck, K. A., Martin, M. T., Richard, A. M., Setzer, R. W., & Kavlock, R. J. (2007) · Toxicological Sciences · doi:10.1093/toxsci/kfl103 · Cited by 1,012
Cell death assays for drug discovery
Kepp, O., Galluzzi, L., Lipinski, M., Yuan, J., & Kroemer, G. (2011) · Nature Reviews Drug Discovery · doi:10.1038/nrd3373 · Cited by 558
Cell-Based Biosensors and Their Application in Biomedicine
Liu, Q., Wu, C., Cai, H., Hu, N., Zhou, J., & Wang, P. (2014) · Chemical Reviews · doi:10.1021/cr2003129 · Cited by 348
ODC1 Is a Critical Determinant of MYCN Oncogenesis and a Therapeutic Target in Neuroblastoma
Hogarty, M. D., Norris, M. D., Davis, K., Liu, X., Evageliou, N. F., Hayes, C. S., Pawel, B., Guo, R., Zhao, H., Sekyere, E., et al. (2008) · Cancer Research · doi:10.1158/0008-5472.can-07-6866 · Cited by 262
Compound Cytotoxicity Profiling Using Quantitative High-Throughput Screening
Xia, M., Huang, R., Witt, K. L., Southall, N., Fostel, J., Cho, M.-H., Jadhav, A., Smith, C. S., Inglese, J., Portier, C. J., et al. (2008) · Environmental Health Perspectives · doi:10.1289/ehp.10727 · Cited by 255
Smout, M. J., Laha, T., Mulvenna, J., Sripa, B., Suttiprapa, S., Jones, A., Brindley, P. J., & Loukas, A. (2009) · PLoS Pathogens · doi:10.1371/journal.ppat.1000611 · Cited by 187
Smout, M. J., Sotillo, J., Laha, T., Papatpremsiri, A., Rinaldi, G., Pimenta, R. N., Chan, L. Y., Johnson, M. S., Turnbull, L., Whitchurch, C. B., et al. (2015) · PLOS Pathogens · doi:10.1371/journal.ppat.1005209 · Cited by 94
Involvement of P38MAPK in human corneal endothelial cell migration induced by TGF-β2
Joko, T., Shiraishi, A., Akune, Y., Tokumaru, S., Kobayashi, T., Miyata, K., & Ohashi, Y. (2013) · Experimental Eye Research · doi:10.1016/j.exer.2012.11.018 · Cited by 49
Metadata
- Authors
- Xing, J. Z., Zhu, L., Jackson, J. A., Gabos, S., Sun, X.-J., Wang, X.-B., & Xu, X.
- Venue
- Chemical Research in Toxicology
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-02-01
- Volume
- 18
- Issue
- 2
- Pages
- 154-161
- ISSN
- 0893-228X (ISSN-L)
- 1520-5010
- OpenAlex
- W2061396971
- Cited by
- 314
- References
- 8
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.