CoChat

Rapid Determination of Glutathione Peroxidase and Thioredoxin Reductase Activities Using a 96-well Microplate Format: Comparison to Standard Cuvette-based Assays

Smith, Allen D., Morris, Virginia C., Levander, Orville A. · 2001 · International Journal for Vitamin and Nutrition Research
Cited by 43

The DOI matches its Crossref record.

Abstract

Gluthatione peroxidase and thioredoxin reductase are selenocysteine-containing enzymes that are constituents of the cellular antioxidant defense system. Conventional cuvette-based assays for glutathione peroxidase and thioredoxin reductase enzymes are laborious and time consuming. The ability to assay their activities rapidly in multiple samples would aid efforts focused on understanding the impact of these enzymes on the cellular antioxidant defense system. High throughput can be achieved with assays adapted to work in a clinical analyzer but require expensive equipment. Assays designed to work in a 96-well microplate reader provide an alternative methodology for high throughput with reduced instrumentation cost. However, due to differences in the light pathlength when using a 96-well format, the values obtained cannot be compared directly with those obtained using a 1-cm cuvette. Described here are assays for glutathione peroxidase and thioredoxin reductase modified to work in a 96-well format that incorporates light pathlength determinations into the assays. The values obtained using a high throughput 96-well format in conjunction with pathlength determinations are in agreement with those obtained using a standard 1-cm cuvette. While spectrophotometrically derived pathlengths are the most accurate, calculated pathlengths based on assay volume and well size can be used with only a small amount of error introduced. This method can also be applied to many other enzyme assays, thus allowing the rapid analysis of large numbers of samples without the need for expensive equipment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1024/0300-9831.71.1.87

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 43

Metadata

Authors
Smith, A. D., Morris, V. C., & Levander, O. A.
Venue
International Journal for Vitamin and Nutrition Research
Publisher
IMR Press
Published
2001-01-01
Volume
71
Issue
1
Pages
87-92
ISSN
  • 0020-9406 (ISSN-L)
  • 0300-9831
  • 1664-2821
OpenAlex
W1976404153
Cited by
43
References
0
FWCI
1.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid Determination of Glutathione Peroxidase and Thioredoxin Reductase Activities Using a 96-well Microplate Format: Comparison to Standard Cuvette-based Assays. https://app.cochat.ai/papers/10.1024/0300-9831.71.1.87
The paper
Smith, A. D., Morris, V. C., & Levander, O. A. (2001). Rapid Determination of Glutathione Peroxidase and Thioredoxin Reductase Activities Using a 96-well Microplate Format: Comparison to Standard Cuvette-based Assays. International Journal for Vitamin and Nutrition Research. https://doi.org/10.1024/0300-9831.71.1.87

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.