CoChat

Comparison of temporary abdominal aortic occlusion with internal iliac artery occlusion for patients with placenta accreta – a non-randomised prospective study

Wang, Yan-Li, Duan, Xu-Hua, Han, Xin-Wei, Wang, Ling, Zhao, Xian-Lan, Chen, Zhi-Min, Chu, Qin-Jun, Zhang, Wei · 2017 · Vasa

The DOI matches its Crossref record.

Abstract

Background: To compare the efficacy of temporary abdominal aortic occlusion with internal iliac artery occlusion for the management of placenta accreta. Patients and methods: 105 patients with placenta accreta were selected for treatment with temporary abdominal aortic occlusion (n = 57, group A) or bilateral iliac artery occlusion (n = 48, group B). Temporary abdominal aortic and internal iliac artery balloon occlusions were performed during caesarean sections. Data regarding the clinical success, blood loss, blood transfusion, balloon insertion time, fluoroscopy time, balloon occlusion time, foetal radiation dose, and complications were collected. Results: Temporary abdominal aortic occlusion and bilateral internal iliac artery occlusion were technically successful in all patients. The amount of blood loss (P < 0.001), amount of blood transfusion (P < 0.001), balloon insertion time (P < 0.001), foetal radiation dose (P < 0.001) and fluoroscopy time (P < 0.01) in group A were significantly lower than those of patients in group B. No marked differences were found between these 2 groups with respect to age, mean postoperative hospital stay, balloon occlusion time, and Apgar score (p > 0.05). Conclusions: Temporary abdominal aortic balloon occlusion resulted in better clinical outcomes with less blood loss, blood transfusion, balloon insertion time, fluoroscopy time and foetal radiation dose than those in bilateral internal iliac balloon occlusion.

Overview

Integrity signals

Registry

Crossref · 10.1024/0301-1526/a000577

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Still being checked.

Cited by

See all 60

Metadata

Authors
Wang, Y.-L., Duan, X.-H., Han, X.-W., Wang, L., Zhao, X.-L., Chen, Z.-M., Chu, Q.-J., & Zhang, W.
Affiliations
  • Department of Interventional Radiology, The First Affiliated Hospital, Zhengzhou University, Zhengzhou, Henan Province, China
  • Zhengzhou University (CN)
  • Department of Anesthesiology, The First Affiliated Hospital, Zhengzhou University, Zhengzhou, Henan Province, China
Venue
Vasa
Published
2017-01-01
Volume
46
Issue
1
Pages
53-57
ISSN
  • 0301-1526 (ISSN-L)
  • 1664-2872
OpenAlex
W2516685152
Cited by
60
References
0
Citations by year
2026: 3 · 2025: 1 · 2024: 3 · 2023: 3 · 2022: 8 · 2021: 14 · 2020: 9 · 2019: 10 · 2018: 5 · 2017: 4
FWCI
7.36
Type
journal article
Language
en
Open access
closed
Locations
  • VASA (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Maternal and fetal healthcare
  • Health Sciences › Medicine › Hematology › Blood transfusion and management
  • Health Sciences › Medicine › Hematology › Hemostasis and retained surgical items
Keywords
placenta accreta, internal iliac artery occlusion, balloon occlusion, cesarean section, haemorrhage management, blood loss, blood transfusion, fluoroscopy time, postoperative complications
MeSH terms
Adult, Aorta, Abdominal, Aortography, Blood Transfusion, Cesarean Section, Female, Postpartum Hemorrhage, Humans, Iliac Artery, Magnetic Resonance Imaging, Placenta Accreta, Pregnancy, Prospective Studies, Regional Blood Flow, Time Factors, Angiography, Digital Subtraction, Treatment Outcome, Balloon Occlusion, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of temporary abdominal aortic occlusion with internal iliac artery occlusion for patients with placenta accreta – a non-randomised prospective study. https://app.cochat.ai/papers/10.1024/0301-1526/a000577
The paper
Wang, Y.-L., Duan, X.-H., Han, X.-W., Wang, L., Zhao, X.-L., Chen, Z.-M., Chu, Q.-J., & Zhang, W. (2017). Comparison of temporary abdominal aortic occlusion with internal iliac artery occlusion for patients with placenta accreta – a non-randomised prospective study. Vasa. https://doi.org/10.1024/0301-1526/a000577

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.