The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Influence of pore fluid chemistry on the complex conductivity and induced polarization responses of Berea sandstone
Abstract
The spectral induced‐polarization (IP) response of rocks and soils is a complex function of pore solution chemistry, sample microgeometry, and surface chemical properties. We measure the complex conductivity and the time domain IP responses of Berea sandstone as a function of pore fluid ionic strength and pH. Complex conductivity is measured over the frequency range 10−3 to 10 6 Hz, and chargeability is computed using a time window of 0.16 to 1.74 s. The field IP parameters: phase, percent frequency effect, and chargeability are functions of both the surface and bulk electrical properties of the sample and are observed to decrease with increasing solution conductivity. Dividing these parameters by the sample resistivity yields normalized IP parameters (quadrature conductivity, metal factor, normalized chargeability) that are proportional to the imaginary component of the complex surface conductivity. Normalized IP parameters increase with ionic strength up to concentrations of 10−1 M NaCl and show a reduced response at pH 3, the point of zero charge for quartz‐dominated systems. For concentrations >10−1 M NaCl, the normalized parameters decrease with increasing concentration. This decrease in surface polarization may indicate a decrease in the effective mobility of polarizing charges at high solution concentration. Our data indicate that normalized IP parameters are directly related to the physiochemical parameters that control the surface conductivity responses of rocks and soils. Normalization of IP measurements in environmental investigations should increase the effectiveness of IP surveys, especially in high‐conductivity environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
The Electrical Resistivity Log as an Aid in Determining Some Reservoir Characteristics
Archie, G. E. (1942) · Transactions of the AIME · doi:10.2118/942054-g · Cited by 7,761
Sen, P. N., Scala, C., & Cohen, M. H. (1981) · Geophysics · doi:10.1190/1.1441215 · Cited by 1,070
Theoretical and Experimental Bases for the Dual-Water Model for Interpretation of Shaly Sands
Clavier, C., Coates, G., & Dumanoir, J. (1984) · Society of Petroleum Engineers Journal · doi:10.2118/6859-pa · Cited by 541
James, R. O., & Parks, G. A. (1982) · Surface and Colloid Science · doi:10.1007/978-1-4613-3204-6_2 · Cited by 407
The properties of a dielectric containing semiconducting particles of various shapes
Sillars, R. W. (1937) · The journal of the Institution of Electrical Engineers · doi:10.1049/jiee-1.1937.0058 · Cited by 365
The dielectric constant of sandstones, 60 kHz to 4 MHz
Knight, R. J., & Nur, A. (1987) · Geophysics · doi:10.1190/1.1442332 · Cited by 283
Dielectric spectroscopy of sedimentary rocks
Lesmes, D. P., & Morgan, F. D. (2001) · Journal of Geophysical Research: Solid Earth · doi:10.1029/2000jb900402 · Cited by 262
Self-citationA generalized Maxwell-Wagner theory for membrane polarization in shaly sands
de Lima, O. A. L., & Sharma, M. M. (1992) · Geophysics · doi:10.1190/1.1443257 · Cited by 176
An Experimental Investigation of the S.P. and Resistivity Phenomena in Dirty Sands
Wyllie, M. R. J., & Southwick, P. F. (1954) · Journal of Petroleum Technology · doi:10.2118/302-g · Cited by 143
Cited by
Soil properties influencing apparent electrical conductivity: a review
Friedman, S. P. (2005) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2004.11.001 · Cited by 798
Revil, A. (2013) · Water Resources Research · doi:10.1029/2012wr012700 · Cited by 378
Slater, L. (2007) · Surveys in Geophysics · doi:10.1007/s10712-007-9022-y · Cited by 364
Electrical‐hydraulic relationships observed for unconsolidated sediments
Slater, L., & Lesmes, D. P. (2002) · Water Resources Research · doi:10.1029/2001wr001075 · Cited by 275
Self-citationDielectric spectroscopy of sedimentary rocks
Lesmes, D. P., & Morgan, F. D. (2001) · Journal of Geophysical Research: Solid Earth · doi:10.1029/2000jb900402 · Cited by 262
Self-citation
Metadata
- Authors
- Lesmes, D. P., & Frye, K. M.
- Venue
- Journal of Geophysical Research: Solid Earth
- Publisher
- American Geophysical Union (AGU)
- Published
- 2001-03-10
- Volume
- 106
- Issue
- B3
- Pages
- 4079-4090
- ISSN
- 0148-0227 (ISSN-L)
- OpenAlex
- W2105371752
- Cited by
- 352
- References
- 11
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of pore fluid chemistry on the complex conductivity and induced polarization responses of Berea sandstone. https://app.cochat.ai/papers/10.1029/2000jb900392
- The paper
- Lesmes, D. P., & Frye, K. M. (2001). Influence of pore fluid chemistry on the complex conductivity and induced polarization responses of Berea sandstone. Journal of Geophysical Research: Solid Earth. https://doi.org/10.1029/2000jb900392
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.