Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 411

The DOI matches its Crossref record.

Design, calibration, and performance of MICROTOPS II handheld ozone monitor and Sun photometer

Morys, Marian, Mims, Forrest M., Hagerup, Scott, Anderson, Stanley E., Baker, Aaron, Kia, Jesse, Walkup, Travis·2001·Journal of Geophysical Research: Atmospheres

Abstract

MICROTOPS II is a five‐channel, handheld Sun photometer that can be configured to measure total ozone, total water vapor, or aerosol optical thickness at various wavelengths. The instrument measures 10×20×4.3 cm and weighs 600 g. A principal design goal was the measurement of total ozone to within 1% of ozone measurements made by much larger, heavier, and more expensive Dobson and Brewer spectrophotometers. This goal has been met for a maximum air mass of up to ∼2.5, as demonstrated by comparisons of MICROTOPS II and its immediate predecessor, Supertops, with Dobson and Brewer instruments at various locations. Conventional interference filters are subject to gradual and unpredictable degradation. MICROTOPS II avoids these problems by using highly stable ultraviolet filters manufactured with an ion deposition process. The 2.4 nm (FWHM) band pass of the UV filters was selected to balance noise and ozone measurement performance. The optical collimators and electronics of the instrument were carefully designed to optimize pointing accuracy, stray light rejection, thermal and long‐term stability, signal‐to‐noise ratio, and data analysis. An internal microcomputer automatically calculates the total ozone column based on measurements at three UV wavelengths, the site's geographic coordinates, and universal time, altitude, and pressure. The coordinates can be entered manually or by a Global Positioning System (GPS) receiver. A built‐in pressure transducer automatically measures pressure. MICROTOPS II saves in nonvolatile memory up to 800 scans of the raw and calculated data. Measurements can be read from a liquid crystal display or transferred to an external computer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1029/2001jd900103

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 411

Metadata

Authors
Morys, M., Mims, F. M., Hagerup, S., Anderson, S. E., Baker, A., Kia, J., & Walkup, T.
Venue
Journal of Geophysical Research: Atmospheres
Published
2001-07
Volume
106
Issue
D13
Pages
14573-14582
ISSN
0148-0227 (ISSN-L)
OpenAlex
W2152809766
Cited by
411
References
0
FWCI
5.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design, calibration, and performance of MICROTOPS II handheld ozone monitor and Sun photometer. https://app.cochat.ai/papers/10.1029/2001jd900103
The paper
Morys, M., Mims, F. M., Hagerup, S., Anderson, S. E., Baker, A., Kia, J., & Walkup, T. (2001). Design, calibration, and performance of MICROTOPS II handheld ozone monitor and Sun photometer. Journal of Geophysical Research: Atmospheres. https://doi.org/10.1029/2001jd900103

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.