Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 331

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Time‐ and size‐resolved chemical composition of submicron particles in Pittsburgh: Implications for aerosol sources and processes

Open access
Zhang, Qi, Canagaratna, Manjula R., Jayne, John T., Worsnop, Douglas R., Jimenez, Jose‐Luis·2005·Journal of Geophysical Research: Atmospheres

Abstract

An Aerodyne aerosol mass spectrometer (AMS) was deployed at the Pittsburgh Environmental Protection Agency Supersite from 7 to 22 September 2002 as part of the Pittsburgh Air Quality Study (PAQS). The main objectives of this deployment were to characterize the concentrations, size distributions, and temporal variations of nonrefractory (NR) chemical species in submicron particles (approximately PM 1) and to further develop and evaluate the AMS. Reasonably good agreement was observed on particle concentrations, composition, and size distributions between the AMS data and measurements from collocated instruments (given the difference between the PM 1 and PM 2.5 size cuts), including TEOM, semicontinuous sulfate, 2‐hour‐ and 24‐hour‐averaged organic carbon, SMPS, 4‐hour‐averaged ammonium, and micro‐orifice uniform deposit impactor. Total NR‐PM 1 mass concentration in Pittsburgh accumulates over periods of several days punctuated with rapid cleaning due to rain or air mass changes. Sulfate and organics are the major NR‐PM 1 components while the concentrations of nitrate and chloride are generally low. Significant amounts of ammonium, which most of the time are consistent with sulfate present as ammonium sulfate, are also present in particles. However, there are periods when the aerosols are relatively acidic and more than 50% of sulfate is estimated to be in the form of ammonium bisulfate. No major enhancement of the organic concentration is observed during these acidic periods, which suggests that acid‐catalyzed SOA formation was not an important process during this study. Size distributions of particulate sulfate, ammonium, organics, and nitrate vary on timescales of hours to days, showing unimodal, bimodal and even trimodal characteristics. The accumulation mode (peaking around 350–600 nm in vacuum aerodynamic diameter for the mass distributions) and the ultrafine mode (<100 nm) are observed most frequently. The accumulation mode is dominated by sulfate that appears to be internally mixed with oxidized organics, while combustion‐emitted organics are often the main component of the ultrafine particles (except during nucleation events). The ultrafine‐mode organic aerosols are mainly associated with combustion sources (likely traffic).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1029/2004jd004649

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 331

Metadata

Authors
Zhang, Q., Canagaratna, M. R., Jayne, J. T., Worsnop, D. R., & Jimenez, J.
Venue
Journal of Geophysical Research: Atmospheres
Published
2005-01-25
Volume
110
Issue
D7
ISSN
0148-0227 (ISSN-L)
OpenAlex
W2053799799
Cited by
331
References
2
FWCI
17.05
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Time‐ and size‐resolved chemical composition of submicron particles in Pittsburgh: Implications for aerosol sources and processes. https://app.cochat.ai/papers/10.1029/2004jd004649
The paper
Zhang, Q., Canagaratna, M. R., Jayne, J. T., Worsnop, D. R., & Jimenez, J. (2005). Time‐ and size‐resolved chemical composition of submicron particles in Pittsburgh: Implications for aerosol sources and processes. Journal of Geophysical Research: Atmospheres. https://doi.org/10.1029/2004jd004649

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.