Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 259

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Nitrogen oxide measurements at rural sites in Switzerland: Bias of conventional measurement techniques

Open access
Steinbacher, M., Zellweger, C., Schwarzenbach, B., Bugmann, S., Buchmann, B., Ordóñez, C., Prevot, A. S. H., Hueglin, C.·2007·Journal of Geophysical Research: Atmospheres

Abstract

Nitrogen oxides (NOx = NO + NO 2) in the atmosphere are often measured using instruments equipped with molybdenum converters. NO 2 is catalytically converted to NO on a heated molybdenum surface and subsequently measured by chemiluminescence after reaction with ozone. The drawback of this technique is that other oxidized nitrogen compounds such as peroxyacetyl nitrate and nitric acid are also partly converted to NO. Thus such NO 2 measurements are really surrogate NO 2 measurements because the resultant values systematically overestimate the true value because of interferences of these compounds, especially when sampling photochemically aged air masses. However, molybdenum converters are widely used, and a dense network of surrogate NO 2 measurements exists. As an alternative with far less interference, photolytic converters using ultraviolet light are nowadays applicable also for long‐term measurements. This work presents long‐term collocated NO 2 measurements using molybdenum and photolytic converters at two rural sites in Switzerland. On a relative scale, the molybdenum converter instruments overestimate the NO 2 concentrations most during spring/summer because of prevalent photochemistry. On a monthly basis, only 70–83% of the “surrogate” NO 2 can be attributed to “real” NO 2 at the non‐elevated site and even less (43–76%) at the elevated one. The observed interferences have to be taken into account for monitoring and regulatory issues and to be considered when using these data for ground‐truthing of satellite data or for validation of chemical transport models. Alternatively, an increased availability of artifact‐free data would also be beneficial for these issues.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1029/2006jd007971

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 259

Metadata

Authors
Steinbacher, M., Zellweger, C., Schwarzenbach, B., Bugmann, S., Buchmann, B., Ordóñez, C., Prevot, A. S. H., & Hueglin, C.
Venue
Journal of Geophysical Research: Atmospheres
Published
2007-06-12
Volume
112
Issue
D11
ISSN
0148-0227 (ISSN-L)
OpenAlex
W2036980759
Cited by
259
References
33
FWCI
8.89
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nitrogen oxide measurements at rural sites in Switzerland: Bias of conventional measurement techniques. https://app.cochat.ai/papers/10.1029/2006jd007971
The paper
Steinbacher, M., Zellweger, C., Schwarzenbach, B., Bugmann, S., Buchmann, B., Ordóñez, C., Prevot, A. S. H., & Hueglin, C. (2007). Nitrogen oxide measurements at rural sites in Switzerland: Bias of conventional measurement techniques. Journal of Geophysical Research: Atmospheres. https://doi.org/10.1029/2006jd007971

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.