The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
What do the HIRM and S‐ratio really measure in environmental magnetism?
Abstract
The “hard” isothermal remanent magnetization (HIRM) and the S‐ratio are widely used in environmental magnetism to quantify the absolute and relative concentrations, respectively, of antiferromagnetic minerals (hematite and goethite) in mineral mixtures. We demonstrate that synthetic Al‐substituted hematite and goethite exhibit a wide range of coercivities, which significantly influences the HIRM and S‐ratio. These parameters are therefore not necessarily straightforward indicators of the absolute and relative concentrations of hematite/goethite. To circumvent this problem, we propose a new parameter (the L‐ratio), which is the ratio of two remanences after alternating field (AF) demagnetization of an IRM imparted in a 1 T field with a peak AF of 100 mT and 300 mT: IRM AF@300mT/IRM AF@100mT. These parameters are easily measured using modern vibrating sample or alternating gradient magnetometers. Changes in HIRM only reflect changes in the absolute concentration of hematite and/or goethite if the L‐ratio is relatively constant. Conversely, L‐ratio fluctuations indicate variable coercivities that possibly reflect changes in the source of hematite/goethite. Corresponding HIRM and S‐ratio variations should be interpreted with caution in such cases. The L‐ratio can be determined using equivalent terms depending on available instrumentation and measurement protocols. For example, the HIRM is equivalent to IRM AF@300mT. Likewise, 0.5*(SIRM + IRM−100mT), where IRM−100mT represents the remanent magnetization obtained by first saturating the sample in a high field and then applying a back‐field of −100 mT, is equivalent to IRM AF@100mT. The HIRM/[0.5*(SIRM + IRM−100mT)] ratio is therefore a suitable substitute for the L‐ratio when measurements are made with a long‐core magnetometer. The newly proposed L‐ratio is straightforward to measure on a wide range of instruments and can provide significant new insights and reduce ambiguities associated with interpretation of two widely used parameters in environmental magnetism, the HIRM and S‐ratio.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rock Magnetism: Fundamentals and Frontiers
Dunlop, D. J., & Özdemir, Ö. (1997) · doi:10.1017/cbo9780511612794 · Cited by 1,817
Cited by
Environmental magnetism: Principles and applications
Liu, Q., Roberts, A. P., Larrasoaña, J. C., Banerjee, S. K., Guyodo, Y., Tauxe, L., & Oldfield, F. (2012) · Reviews of Geophysics · doi:10.1029/2012rg000393 · Cited by 776
Self-citation
Metadata
- Authors
- Liu, Q., Roberts, A. P., Torrent, J., Horng, C., & Larrasoaña, J. C.
- Venue
- Geochemistry, Geophysics, Geosystems
- Publisher
- American Geophysical Union (AGU)
- Published
- 2007-09
- Volume
- 8
- Issue
- 9
- ISSN
- 1525-2027 (ISSN-L)
- OpenAlex
- W1504293909
- Cited by
- 242
- References
- 1
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: What do the HIRM and S‐ratio really measure in environmental magnetism? https://app.cochat.ai/papers/10.1029/2007gc001717
- The paper
- Liu, Q., Roberts, A. P., Torrent, J., Horng, C., & Larrasoaña, J. C. (2007). What do the HIRM and S‐ratio really measure in environmental magnetism? Geochemistry, Geophysics, Geosystems. https://doi.org/10.1029/2007gc001717
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.