Cited by 248Calibration and Measurement TechniquesGeochemistry and Geologic MappingPlanetary Science and Exploration

The DOI matches its Crossref record.

Quantitative thermal emission spectroscopy of minerals: A laboratory technique for measurement and calibration

Open access
Ruff, Steven W., Christensen, Philip R., Barbera, Paul W., Anderson, Donald L.·1997·Journal of Geophysical Research: Solid Earth

Abstract

Previous descriptions of thermal emission spectroscopy have presented techniques that vary in accuracy and reproducibility. Contributions of thermal energy from the instrument and environment are major calibration factors that limit accuracy in emissivity determination. Reproducibility is related to the stability of these quantities. Sample temperature determination is also a significant factor in arriving at accurate emissivity. All of the factors which impact the measurement of emissivity using an interferometric spectrometer with an uncooled detector are isolated and examined here. An experimental apparatus is presented along with a description of a simplified measurement and calibration scheme used to arrive at quantitative emissivity of minerals. A detailed error analysis examines the effect of errors in each of the calibration parameters in isolation and as part of multiple error propagation. Sample temperature determination from radiance can create emissivity error, but 95% of published minerals have an emissivity maximum of 0.98 or higher, resulting in emissivity error of 2% or less. With worst‐case systematic and random errors included, emissivity can be determined with an uncertainty of ∼4%. In most cases it is less than 2%. Reproducibility with this technique is better than 1%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1029/97jb00593

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 29

  1. 10.1364/AO.14.002927 · DOI
  2. 10.1366/0003702814731860 · DOI
  3. 10.1029/93JB00135 · DOI
  4. 10.1029/JB074i006p01614 · DOI
  5. 10.1366/0003702874448436 · DOI
  6. 10.1366/0003702914337029 · DOI
  7. 10.1366/000370272774352650 · DOI
  8. 10.1366/0003702864509132 · DOI
  9. 10.1029/JC077i015p02629 · DOI
  10. Hawthorne F. C. Spectroscopic Methods in Mineralogy and Geology Rev. Mineral 18 Mineral. Soc. of Am. Washington D.C. 1988. · DOI
  11. 10.1364/JOSA.38.000775 · DOI
  12. Hirschfeld T., 1979, Fourier Transform Infrared Spectroscopy
  13. 10.1016/0584-8539(79)80160-9 · DOI
  14. Kieffer S. W., 1985, Microscopic to Macroscopic: Atomic Environments to Mineral Thermodynamics, Rev. Mineral, 65, 10.1515/9781501508868-005 · DOI
  15. 10.1364/AO.5.001453 · DOI
  16. 10.2113/gsecongeo.60.4.715 · DOI
  17. 10.1016/B978-0-12-399950-4.50012-4 · DOI
  18. McGuire J. A., 1992, Modifications to a commercial infrared emission apparatus to permit quantitative applications, Appl. Spectrosc., 46, 178, 10.1366/0003702924444263 · DOI
  19. 10.1111/j.1151-2916.1951.tb13492.x · DOI
  20. McMillan P., 1985, Microscopic to Macroscopic: Atomic Environments to Mineral Thermodynamics, Rev. Mineral, 9, 10.1515/9781501508868-004 · DOI
  21. Mertz L., 1965, Transformations in Optics
  22. 10.1029/JB095iB05p07027 · DOI
  23. 10.1366/0003702914337687 · DOI
  24. 10.1016/0034-4257(92)90092-X · DOI
  25. Salisbury J. W., 1991, Infrared (2.1–25 μm) Spectra of Minerals
  26. 10.1029/93JB03600 · DOI
  27. 10.1364/AO.2.001169 · DOI
  28. 10.1366/0003702924124844 · DOI
  29. 10.1029/96JB01153 · DOI

Cited by

Sorted by citations

Metadata

Authors
Ruff, S. W., Christensen, P. R., Barbera, P. W., & Anderson, D. L.
Affiliations
Arizona State University (US)
Venue
Journal of Geophysical Research: Solid Earth
Published
1997-07-10
Volume
102
Issue
B7
Pages
14899-14913
ISSN
0148-0227 (ISSN-L)
OpenAlex
W2000024155
Cited by
248
References
0
Citations by year
2026: 3 · 2025: 8 · 2024: 11 · 2023: 6 · 2022: 7 · 2021: 11 · 2020: 15 · 2019: 14 · 2018: 9 · 2017: 9 · 2016: 14 · 2015: 8 · 2014: 6 · 2013: 12 · 2012: 9
FWCI
15.78
Type
journal article
Language
en
Open access
Locations
Journal of Geophysical Research Atmospheres (publishedVersion)
Funders
  • National Aeronautics and Space Administration
  • Arizona State University
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › Calibration and Measurement Techniques
  • Physical Sciences › Earth and Planetary Sciences › Geochemistry and Petrology › Geochemistry and Geologic Mapping
  • Physical Sciences › Earth and Planetary Sciences › Space and Planetary Science › Planetary Science and Exploration
Keywords
thermal emission spectroscopy, emissivity, calibration, interferometric spectrometer, uncooled detectors, radiance, error propagation, measurement uncertainty, reproducibility, thermal infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review