CoChat

Results from the balloon ozone intercomparison campaign (BOIC)

Hilsenrath, E., Attmannspacher, W., Bass, A., Evans, W., Hagemeyer, R., Barnes, R. A., Komhyr, W., Mauersberger, K., Mentall, J., Proffitt, M., Robbins, D., Taylor, S., Torres, A., Weinstock, E. · 1986 · Journal of Geophysical Research: Atmospheres
Cited by 114

The DOI matches its Crossref record.

Abstract

The purpose of the Balloon Ozone Intercomparison Campaign (BOIC) was to assess the accuracy and precision of various ozone measurement systems under development and those flown operationally. Ozone observations made by in situ UV absorption photometers from four groups, two solar UV absorption photometers, three varieties of electrochemical sondes, and a mass spectrometer were intercompared in three flight missions, each involving several balloon flights. Concurrent Umkehr and satellite observations were also intercompared. The National Bureau of Standards (NBS)provided a reference ozone source for intercomparing several of the in situ instruments at ground pressure. Harvard University and the University of Minnesota each developed a calibration facility after the BOIC flights which enabled a comparison of the flight in situ photometers under simulated stratospheric pressure and ozone concentrations. The following is a summary of results. The standard deviation of the sensitivities among 18 instruments tested about the NBS reference was 11%. These differences appear in flight at the lower altitudes, but they change at higher altitudes, indicating height dependent errors, particularly for the electrochemical sondes. Comparisons at the two laboratory facilities simulating stratospheric conditions indicated differences of about 2% at 3 mbar for two of the flight in situ photometers. Ozone values among four in situ UV photometers flown together had a standard deviation about the mean value of about ±3% from the tropopause to about 41 km. This is very close to the expected accuracy of these measurements and therefore is an excellent result. However, during float at 42 km the difference nearly doubled. Experiments performed during flight demonstrated that even near 40 km, wall losses in three UV photometers were less than 5%, which is consistent with the laboratory simulations. A comparison of a complement of electrochemical sondes yielded results that agreed with the mean of the in situ UV photometers to within 0–20%, depending on the sonde type and altitude. The electrochemical sondes gave systematically lower ozone values at pressures lower than 10 mbar (above 31 km). A comparison between an in situ UV and a solar absorption photometer indicated a 10% difference in the stratosphere, where the in situ measurement was lower. Comparisons of electrochemical sondes and Umkehr and Solar backscattered ultraviolet (SBUV) satellite observations showed agreement to within their error bars (stated to be about 5–10%). In two comparisons between in situ UV photometers and satellite measurements, a consistent difference occurred between 10 and 3 mbar (28–40 km), implying a possible bias between the measurement types. Intercomparisons among all the instruments in the troposphere showed 20–30% differences from the mean. A comparison of pressure measurements performed by several experimenters resulted in differences as high as ±15% from the average measurement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1029/jd091id12p13137

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 114

Metadata

Authors
Hilsenrath, E., Attmannspacher, W., Bass, A., Evans, W., Hagemeyer, R., Barnes, R. A., Komhyr, W., Mauersberger, K., Mentall, J., Proffitt, M., Robbins, D., Taylor, S., Torres, A., & Weinstock, E.
Venue
Journal of Geophysical Research: Atmospheres
Published
1986-11-20
Volume
91
Issue
D12
Pages
13137-13152
ISSN
0148-0227 (ISSN-L)
OpenAlex
W2013179315
Cited by
114
References
0
FWCI
7.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Results from the balloon ozone intercomparison campaign (BOIC). https://app.cochat.ai/papers/10.1029/jd091id12p13137
The paper
Hilsenrath, E., Attmannspacher, W., Bass, A., Evans, W., Hagemeyer, R., Barnes, R. A., Komhyr, W., Mauersberger, K., Mentall, J., Proffitt, M., Robbins, D., Taylor, S., Torres, A., & Weinstock, E. (1986). Results from the balloon ozone intercomparison campaign (BOIC). Journal of Geophysical Research: Atmospheres. https://doi.org/10.1029/jd091id12p13137

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.