The Mechanism of Natural Ground‐Water Recharge and Discharge: 1. One‐dimensional, Vertical, Unsteady, Unsaturated Flow above a Recharging or Discharging Ground‐Water Flow System
Abstract
The unsaturated flow processes of infiltration and evaporation are in physical and mathematical continuity with the parallel saturated processes of recharge and discharge. Water table fluctuations result when the rate of ground‐water recharge or discharge is not matched by the unsaturated flow rate created by infiltration or evaporation. A water‐table rise provides the source of replenishment to the ground‐water zone that allows the prevailing rate of recharge to continue. This dynamic water‐table behavior can be simulated by a one‐dimensional, numerical mathematical model involving transient flow through an integrated saturated‐unsaturated system. The solutions are applicable to homogeneous, isotropic soils in which the functional relationships show hysteresis properties. The model allows upper boundary conditions of constant rate rainfall, ponded water, evaporation, and redistribution. It can be used to determine the water‐table fluctuation that will arise from a given set of initial conditions, boundary conditions, and soil type. The effects of variations in the parameters that control the flow are examined to arrive at a better understanding of the mechanism of natural ground‐water recharge and discharge.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Water flow and solute transport processes in the unsaturated zone
Nielsen, D. R., Th. Van Genuchten, M., & Biggar, J. W. (1986) · Water Resources Research · doi:10.1029/wr022i09sp0089s · Cited by 541
Baum, R. L., Godt, J. W., & Savage, W. Z. (2010) · Journal of Geophysical Research: Earth Surface · doi:10.1029/2009jf001321 · Cited by 412
Physically based modeling in catchment hydrology at 50: Survey and outlook
Paniconi, C., & Putti, M. (2015) · Water Resources Research · doi:10.1002/2015wr017780 · Cited by 374
Role of subsurface flow in generating surface runoff: 2. Upstream source areas
Freeze, R. A. (1972) · Water Resources Research · doi:10.1029/wr008i005p01272 · Cited by 366
Self-citationHillslope Hydrology and Stability
Lu, N., & Godt, J. W. (2013) · Cambridge University Press eBooks · doi:10.1017/cbo9781139108164 · Cited by 352
Metadata
- Authors
- Freeze, R. A.
- Venue
- Water Resources Research
- Publisher
- American Geophysical Union (AGU)
- Published
- 1969-02
- Volume
- 5
- Issue
- 1
- Pages
- 153-171
- ISSN
- 0043-1397 (ISSN-L)
- 1944-7973
- OpenAlex
- W2071791169
- Cited by
- 199
- References
- 0
- FWCI
- 79.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Mechanism of Natural Ground‐Water Recharge and Discharge: 1. One‐dimensional, Vertical, Unsteady, Unsaturated Flow above a Recharging or Discharging Ground‐Water Flow System. https://app.cochat.ai/papers/10.1029/wr005i001p00153
- The paper
- Freeze, R. A. (1969). The Mechanism of Natural Ground‐Water Recharge and Discharge: 1. One‐dimensional, Vertical, Unsteady, Unsaturated Flow above a Recharging or Discharging Ground‐Water Flow System. Water Resources Research. https://doi.org/10.1029/wr005i001p00153
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.