The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Detection of soluble HLA‐G molecules in plasma and amniotic fluid
Abstract
Although the cDNA sequence of HLA‐G antigens is compatible with their expression as soluble molecules (sHLA‐G), the determination of native sHLA‐G levels in body fluids has not yet been described. The lack of this information is likely to reflect the difficulties in developing an assay suitable to measure sHLA‐G antigens in the presence of soluble HLA‐A, ‐B and ‐C (sHLA‐I) antigens, since most of the available anti‐HLA‐G mAb do not detect soluble β2‐m associated HLA‐G antigens or crossreact with sHLA‐I antigens. Therefore, we have developed a two‐step assay which eliminates the interference of classical HLA class I antigens. In the first step, the sample is depleted of sHLA‐I antigens and of HLA‐E antigens with mAb TP25.99. Then, HLA‐G antigens are captured with mAb W6/32 and detected with anti‐β2‐m mAb in ELISA. Utilizing this assay, sHLA‐G antigen levels were measured in EDTA plasma from 92 controls with known HLA types, 28 women at delivery and the corresponding cord bloods and in 50 amniotic fluids. Mean sHLA‐G plasma levels did not differ between males (24.9±3.0 SEM ng/ml; n=42) and females (20.1±2.1 SEM ng/ml; n=50). However, sHLA‐G levels in HLA‐A11 positive probands (mean: 13.0±4.4 SEM ng/ml; n=12) were significantly (P<0.05) lower than in HLA‐A11 negative ones (mean: 24.5±2.0 SEM ng/ml; n=80). sHLA‐G levels in women at delivery (mean: 22.9±2.2 SEM ng/ml; n=28) were in the range of controls but were significantly (P<0.001) reduced in the corresponding cord bloods (mean: 13.8±1.5 SEM ng/ml; n=28). sHLA‐G levels in amniotic fluids (mean: 15.5+1.0 SEM ng/ml; n=50) were significantly (P<0.001) lower than in plasma. sHLA‐G levels were 5 and 11% of those of sHLA‐I antigens in plasmas and amniotic fluids, respectively. Individual sHLA‐G levels were not correlated with sHLA‐I levels. SDS‐PAGE analysis of plasma sHLA‐G antigens revealed two molecular variants with a 35 kD and a 27 kD MW corresponding to the sizes of sHLA‐G1 and ‐G2 isoforms. In conclusion, our study has shown that the two‐step assay we have developed is reliable in measuring sHLA‐G antigen levels. This assay will facilitate the analysis of the biological and clinical significance of sHLA‐G antigens in plasma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wegmann, T. G., Lin, H., Guilbert, L., & Mosmann, T. R. (1993) · Immunology Today · doi:10.1016/0167-5699(93)90235-d · Cited by 2,852
Cited by
HLA‐G and immune tolerance in pregnancy
Hunt, J. S., Petroff, M. G., McIntire, R. H., & Ober, C. (2005) · The FASEB Journal · doi:10.1096/fj.04-2078rev · Cited by 524
Fournel, S., Aguerre-Girr, M., Huc, X., Lenfant, F., Alam, A., Toubert, A., Bensussan, A., & Le Bouteiller, P. (2000) · The Journal of Immunology · doi:10.4049/jimmunol.164.12.6100 · Cited by 463
Carosella, E. D., Rouas-Freiss, N., Roux, D. T.-L., Moreau, P., & LeMaoult, J. (2015) · Advances in Immunology · doi:10.1016/bs.ai.2015.04.001 · Cited by 395
HLA-G Molecules: from Maternal–Fetal Tolerance to Tissue Acceptance
CAROSELLA, E. D., MOREAU, P., LE MAOULT, J., LE DISCORDE, M., DAUSSET, J., & ROUAS-FREISS, N. (2003) · Advances in Immunology · doi:10.1016/s0065-2776(03)81006-4 · Cited by 371
Contini, P., Ghio, M., Poggi, A., Filaci, G., Indiveri, F., Ferrone, S., & Puppo, F. (2003) · European Journal of Immunology · doi:10.1002/immu.200390015 · Cited by 358
Self-citation
Metadata
- Authors
- Rebmann, V., Pfeiffer, K., Päßler, M., Ferrone, S., Maier, S., Weiss, E., & Grosse‐Wilde, H.
- Venue
- Tissue Antigens
- Publisher
- Wiley
- Published
- 1999-01
- Volume
- 53
- Issue
- 1
- Pages
- 14-22
- ISSN
- 0001-2815 (ISSN-L)
- 1399-0039
- OpenAlex
- W1973533652
- Cited by
- 185
- References
- 1
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of soluble HLA‐G molecules in plasma and amniotic fluid. https://app.cochat.ai/papers/10.1034/j.1399-0039.1999.530102.x
- The paper
- Rebmann, V., Pfeiffer, K., Päßler, M., Ferrone, S., Maier, S., Weiss, E., & Grosse‐Wilde, H. (1999). Detection of soluble HLA‐G molecules in plasma and amniotic fluid. Tissue Antigens. https://doi.org/10.1034/j.1399-0039.1999.530102.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.