Split-night versus full-night studies for sleep apnoea/hypopnoea syndrome
Open accessAbstract
Investigation and treatment of sleep apnoea/hypopnoea syndrome (SAHS) is placing increasing demands on healthcare resources. This workload may be reduced by using split-night studies instead of the standard full-nights of diagnostic polysomnography and continuous positive airway pressure (CPAP) titration. Split-night studies involve polysomnography in the first half of the night followed, if there is an abnormal frequency of apnoeas and hypopneas, by CPAP titration for the remainder of the night. The authors' database of all patients prescribed a CPAP trial 1991-1997 was used to compare long-term outcomes in all 49 (46 accepting CPAP) patients prescribed split-night studies with those in full-night patients, matched 1:2 using an apnoea/ hypopnoea index (AHI) of +/-15% and Epworth score of +/-3 units. Classical symptoms of SAHS were the main reason for the split-night studies (n=27). There were no differences between the groups in long-term CPAP use, median nightly CPAP use (split-night 6.0 h x night-1, interquartile range (IQR) 3.8-7.4, full-night; 6.2 h x night-1, IQR 3.7-7.0, p=0.9), post-treatment Epworth scores and frequency of nursing interventions/clinic visits required. The median time from referral to treatment was less for the split-night patients (13 months, IQR 11-20 months) than for full-night patients (22 months, IQR 12-34 months; p=0.003). Split-night studies, in selected patients, result in equivalent long-term continuous positive airway pressure use to full-night studies with shorter treatment times and less healthcare utilization.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Split-night titration is not significantly different from full-night titration in subjective sleepiness or adherence over time.
“Split-night titration, where the first couple of hours of the PSG are for diagnostic purposes and the remainder of the study involves PAP titration, compared to a fullnight titration, is not significantly different in terms of outcomes such as subjective sleepiness or adherence over time.1081–1083”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [1082]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 29 · Cited by 84
Research works printed but not linked: 5
- [4]4. Smith I, Shneerson J. Is the SF36 sensitive to sleep dis- ruption? A study in subjects with sleep apnoea. J Sleep Res 1995; 4: 183±188.
- [15]15. Gould G, Whyte K, Rhind G, et al. The sleep hypopnoea syndrome. Am Rev Respir Dis 1988; 137: 895±898.
- [16]16. Douglas N, Thomas S, Jan M. Clinical value of poly- somnography. Lancet 1992; 339: 347±350.
- [20]20. Charbonneau M, Martin J, Olha A, Kimoff J, Levy R, Cosio M. Changes on obstructive sleep apnea character- istics through the night. Chest 1994; 106: 1695±1701.
- [26]26. Guilleminault C. Clinical features and evaluation of ob- structive sleep apnea. In: Kryger MH, Roth T, Dement W, eds. Principles and Practice of Sleep Medicine. Phila- delphia, W.B. Saunders, 1989; p. 552±558.
- Authors
- McArdle, N., Grove, A., Devereux, G., Mackay-Brown, L., Mackay, T., & Douglas, N. J.
- Affiliations
- University of Edinburgh (GB)
- Edinburgh Royal Infirmary (GB)
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2000-04
- Volume
- 15
- Issue
- 4
- Pages
- 670-675
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2129224741
- Semantic Scholar
- 04a695ae6f56b1ecce57059b9abf1d18ba084840
- Cited by
- 84
- References
- 29
- Citations by year
- 2025: 2 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 3 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 5 · 2016: 3 · 2015: 4 · 2014: 1 · 2013: 4 · 2012: 2
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- European Respiratory Journal (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology › Obstructive Sleep Apnea Research
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Keywords
- sleep apnea-hypopnea syndrome, split-night polysomnography, CPAP titration, CPAP adherence, apnea-hypopnea index, health care utilization, treatment duration, nursing interventions
- MeSH terms
- Adult, Cost-Benefit Analysis, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Night Care, Positive-Pressure Respiration, Probability, Sensitivity and Specificity, Sleep Apnea Syndromes, Time Factors, Linear Models, Proportional Hazards Models, Health Care Costs, Polysomnography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review