The DOI matches its Crossref record.
Tidal breath analysis for infant pulmonary function testing
Abstract
The aim of this position paper is to provide recommendations pertaining to software and equipment requirements when analysing tidal breathing measurements in infants. These guidelines cover numerous aspects including terminology and definitions, equipment, data acquisition and analysis, and reporting of results, and highlight areas in which further research is needed before consensus can be reached. When collecting tidal breathing data in infants and children, equipment dead space and resistance must be minimized, all sources of leak eliminated, and a flowmeter with appropriate frequency response and linearity employed. Inspired gases should be corrected to body temperature, barometric pressure and saturated with water vapour conditions and efforts made to eliminate the various sources of drift in volume that can occur. In addition, the analogue-to-digital converter used to sample data must be capable of adequately resolving the highest and lowest flows required by the study. An adequate sampling rate must be used; 50-100 Hz may be sufficient for the determination of timing and volume parameters, especially in older infants, but rates of 200 Hz are recommended for analysis of the tidal breathing flow/volume loop and other sensitive parameters such as time to peak tidal expiratory flow/expiratory time. The potentially most troublesome aspect of tidal breath analysis from the computational point of view is the identification of the beginning and end of inspiration and expiration. Once methods and equipment for the measurement and analysis of tidal breathing in infants have been standardized, there is an urgent need to establish appropriate reference ranges for various key parameters so that they may be used more effectively in the clinical setting. Implementation of these recommendations should help to ensure that such measurements are as accurate as possible and that more meaningful comparisons can be made between data collected in different centres or with different equipment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Beydon, N., Davis, S. D., Lombardi, E., Allen, J. L., Arets, H. G. M., Aurora, P., Bisgaard, H., Davis, G. M., Ducharme, F. M., Eigen, H., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200605-642st · Cited by 1,250
Self-citationConsensus statement for inert gas washout measurement using multiple- and single- breath tests
Robinson, P. D., Latzin, P., Verbanck, S., Hall, G. L., Horsley, A., Gappa, M., Thamrin, C., Arets, H. G. M., Aurora, P., Fuchs, S. I., et al. (2013) · European Respiratory Journal · doi:10.1183/09031936.00069712 · Cited by 785
Self-citationStatement on the Care of the Child with Chronic Lung Disease of Infancy and Childhood
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.168.3.356 · Cited by 338
McEvoy, C. T., Schilling, D., Clay, N., Jackson, K., Go, M. D., Spitale, P., Bunten, C., Leiva, M., Gonzales, D., Hollister-Smith, J., et al. (2014) · JAMA · doi:10.1001/jama.2014.5217 · Cited by 217
Metadata
- Authors
- Bates, J. H. T., Schmalisch, G., Filbrun, D., Stocks, J., & on behalf of theErs/ats Task Force on Standards for Infant Respiratory Function Testing
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2000-12
- Volume
- 16
- Issue
- 6
- Pages
- 1180-1192
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W1934612251
- Cited by
- 241
- References
- 0
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.