The DOI matches its Crossref record.
Skin conductance correlates with perioperative stress
Abstract
Background: Skin conductance (SC) as a measure of emotional state or arousal may be a tool for monitoring surgical stress in anaesthesia. When an outgoing sympathetic nervous burst occurs to the skin, the palmar and plantar sweat glands are filled up, and the SC increases before the sweat is removed and the SC decreases. This creates a SC fluctuation. The purpose of this study was to measure SC during laparoscopic cholecystectomy with propofol and remifentanil anesthaesia and to evaluate whether number and amplitude of SC fluctuations correlate with perioperative stress monitoring. Methods: Eleven patients were studied nine times before, during and after anaesthesia. SC was compared to changes in stress measures such as blood pressure, heart rate, norepinephrine and epinephrine levels. SC was also compared to changes in Bispectral index (BIS). Results: The blood pressure, epinephrine levels and norepinephrine levels were positively correlated with both the number (P < 0.001) and amplitude (P < 0.01) of the SC fluctuations. Moreover, the BIS was positively correlated with the number (P < 0.001) and amplitude (P < 0.001) of the SC fluctuations. Furthermore, during tracheal intubation, the mean levels of the number of SC fluctuations from the 11 patients had the same stress response as measured in changes of the mean levels of norepinephrine. The mean BIS did not show any stress response during tracheal intubation. Conclusion: Number of SC fluctuations may be a useful method for monitoring the perioperative stress.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ressler, K. J., Rothbaum, B. O., Tannenbaum, L., Anderson, P., Graap, K., Zimand, E., Hodges, L., & Davis, M. (2004) · Archives of General Psychiatry · doi:10.1001/archpsyc.61.11.1136 · Cited by 1,063
Assessment of surgical stress during general anaesthesia
Huiku, M., Uutela, K., van Gils, M., Korhonen, I., Kymäläinen, M., Meriläinen, P., Paloheimo, M., Rantanen, M., Takala, P., Viertiö-Oja, H., et al. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem004 · Cited by 317
Self-Regulation of Breathing as a Primary Treatment for Anxiety
Jerath, R., Crawford, M. W., Barnes, V. A., & Harden, K. (2015) · Applied Psychophysiology and Biofeedback · doi:10.1007/s10484-015-9279-8 · Cited by 293
Assessing pain objectively: the use of physiological markers
Cowen, R., Stasiowska, M. K., Laycock, H., & Bantel, C. (2015) · Anaesthesia · doi:10.1111/anae.13018 · Cited by 285
Changes in skin conductance as a tool to monitor nociceptive stimulation and pain
Storm, H. (2008) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e3283183fe4 · Cited by 260
Self-citation
Metadata
- Authors
- Storm, H., Myre, K., Rostrup, M., Stokland, O., Lien, M. D., & Ræder, J. C.
- Venue
- Acta Anaesthesiologica Scandinavica
- Publisher
- Wiley
- Published
- 2002-07-24
- Volume
- 46
- Issue
- 7
- Pages
- 887-895
- ISSN
- 0001-5172 (ISSN-L)
- 1399-6576
- OpenAlex
- W2004403881
- Cited by
- 179
- References
- 0
- FWCI
- 2.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Skin conductance correlates with perioperative stress. https://app.cochat.ai/papers/10.1034/j.1399-6576.2002.460721.x
- The paper
- Storm, H., Myre, K., Rostrup, M., Stokland, O., Lien, M. D., & Ræder, J. C. (2002). Skin conductance correlates with perioperative stress. Acta Anaesthesiologica Scandinavica. https://doi.org/10.1034/j.1399-6576.2002.460721.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.