Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 190

The DOI matches its Crossref record.

Ligature‐induced peri‐implant infection in cynomolgus monkeys.Clinical and radiographic findings.

Lang, N. P., Brägger, U., Walther, D., Bearner, B., Kornman, K. S.·1993·Clinical Oral Implants Research

Abstract

The purpose of this study was to compare the effect of plaque accumulation in conjunction with or without placement of plaque‐retaining ligatures on peri‐implant and periodontal tissues. Four cynomolgus monkeys received 2 ITI (Type F) dental implants in edentulous areas of each side of the mandible. Following a healing period of 2 months with regular prophylaxis procedures twice per week, plaque was allowed to accumulate. After 1 month (day 0), silk ligatures were placed around 1 of the 2 implants. The third molars served as controls and were ligated as well. Clinical examinations comprising Plaque Index (PlI), Gingival Index (GI), probing depth (PD) and loss of attachment (LA) were performed at the test and control sites before and 1, 2, 3, 4, 5, 6, 7 and 8 months after ligature placement. Sixty and 30 days prior to ligation and at 2, 5, 6 and 8 months following ligation, standardized radiographs were obtained and subtracted from a baseline radiograph obtained at the time of ligation. PI1 and GI scores increased significantly following the elimination of prophylaxis procedures. After ligation, these indices continued to increase and reached values significantly higher in ligated implant (LI) and ligated teeth (LT) sites than in non‐ligated teeth (NLI) sites. PD also increased after plaque accumulation and ligature placement. Significantly greater PD values were noted in LI and LT sites than in NLI sites. Also, loss of attachment was observed already after 1 month following ligation in LI and LT sites and reached a value of 3.8 mm after 8 months, whereas only 1.0 mm of attachment was lost after 7 months of plaque accumulation in NLI. Similar results were noted in the analysis of the subtraction images. LI and LT sites lost significantly more bone density and more alveolar bone height, but the NLI sites yielded relatively stable conditions throughout the study. It is concluded that the development of a peri‐implant infection progressed at a similar rate as the development of a periodontitis lesion and that ligature placement significantly promoted the development of these lesions when compared with the development of an inflammatory response in the peri‐implant tissues as a result of bacterial plaque accumulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-0501.1993.040101.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 190

Metadata

Authors
Lang, N. P., Brägger, U., Walther, D., Bearner, B., & Kornman, K. S.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
1993-03
Volume
4
Issue
1
Pages
2-11
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W2095990072
Cited by
190
References
0
FWCI
6.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ligature‐induced peri‐implant infection in cynomolgus monkeys.Clinical and radiographic findings. https://app.cochat.ai/papers/10.1034/j.1600-0501.1993.040101.x
The paper
Lang, N. P., Brägger, U., Walther, D., Bearner, B., & Kornman, K. S. (1993). Ligature‐induced peri‐implant infection in cynomolgus monkeys.Clinical and radiographic findings. Clinical Oral Implants Research. https://doi.org/10.1034/j.1600-0501.1993.040101.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.