Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 224

The DOI matches its Crossref record.

The effect of a deproteinized bovine bone mineral on bone regeneration around titanium dental implants®

Hämmerle, Christoph H. F., Chiantella, Giovanni C., Karring, Thorkild, Lang1, Niklaus P.·1998·Clinical Oral Implants Research

Abstract

The aim of the present experiment was to test the effect of a deproteinized bovine bone mineral (Bio‐Ossa®) on guided bone regeneration (GBR&) in dehiscence defects around implants. The first 2 molars and all premolars were extracted on both sides of the mandibles of 3 monkeys (Macaca fuscicularis). Three months later, 2 titanium plasma‐coated cylindrical implants were placed in all quadrants of each monkey. During the surgical procedure, standardized dehiscence defects were produced buccally and lingually, measuring 2.5 mm in width and 3 mm in height. Four different experimental situations were created: 2 sites in each monkey were covered with an e‐PTFF membrane (M), 2 were filled with the graft material (DBBM), 2 were filled with the graft material and also covered with a membrane (M+DBBM), and 2 control sites were neither grafted nor covered (C). The flaps were sutured to allow for primary healing. Linear measurements of bone height and width were calculated on histological specimens obtained 6 months following surgery. In addition, values for bone density and for surface fraction of graft to new bone contact were measured. Vertical bone growth along the implant surface of 100% (SD 0%) for M+DBBM, 91% (SD 9%) for M, 52% (SD 24%) for DBBM, and 42% (SD 35%) for C was measured. The width of the regenerated bone 1.5 mm above the bottom of the original defect, i.e. at the 50% mark of the vertical extension of the defect, in relation to the width at the bottom of the defect amounted to 97% (SD 2%) for M+DBBM, 85% (SD 9%) for M, 42% (SD 41%) for DBBM, and 23% (SD 31%) for C. Assessment of bone density within the confinement of the regenerated bone resulted in an increase of 30% (SD 11%) for M+DBBM, 45% (SD 20%) for M, 33% (SD 20%) for DBBM, and 22% (SD 23%) for C. The values for graft to new bone contact within this compartment amounted to 80% (SD15%) for M+DBBM and 89% (SD 14%) for DBBM. In conclusion, Bio‐Oss® exhibited osteoconductive properties and hence can be recommended for GBR procedures in dehiscence defects with respect to vertical and horizontal growth of bone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-0501.1998.090302.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 224

Metadata

Authors
Hämmerle, C. H. F., Chiantella, G. C., Karring, T., & Lang1, N. P.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
1998-06
Volume
9
Issue
3
Pages
151-162
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W2110375302
Cited by
224
References
0
FWCI
11.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effect of a deproteinized bovine bone mineral on bone regeneration around titanium dental implants®. https://app.cochat.ai/papers/10.1034/j.1600-0501.1998.090302.x
The paper
Hämmerle, C. H. F., Chiantella, G. C., Karring, T., & Lang1, N. P. (1998). The effect of a deproteinized bovine bone mineral on bone regeneration around titanium dental implants®. Clinical Oral Implants Research. https://doi.org/10.1034/j.1600-0501.1998.090302.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.