Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 245

The DOI matches its Crossref record.

Determining optimal surface roughness of TiO2 blasted titanium implant material for attachment, proliferation and differentiation of cells derived from human mandibular alveolar bone

Mustafa, Kamal, Wroblewski, Joanna, Lopez, Blanca Silva, Wennerberg, Ann, Hultenby, Kjell, Arvidson, Kristina · 2001 · Clinical Oral Implants Research

Abstract

In the complex process of bone formation at the implant‐tissue interface, implant surface roughness is an important factor modulating osteoblastic function. In this study, primary cultures of osteoblast‐like cells, derived from human mandibular bone, were used. The aim was to examine the effect of varying surface roughness of titanium implant material on cellular attachment, proliferation and differentiation. A recognized method of increasing surface roughness and enlarging the surface area of titanium implants is by blasting with titanium dioxide particles: the four specimen types in the study comprised surfaces which were machine‐turned only, or blasted after turning, with 63–90 μm, 106–180 μm, or 180–300 μm TiO 2 particles, respectively. The specimens were analyzed by scanning electron microscopy and confocal laser scanning. The turned samples had the smoothest surfaces: average height deviation (S a) of 0.20 μm. The roughest were those blasted with 180–300 μm particles, S a value 1.38 μm. Blasting with intermediate particle sizes yielded S a values of 0.72 μm and 1.30 μm, respectively. Cell profile areas were measured using a semiautomatic interactive image analyzer. Figures were expressed as percentage of attachment. DNA synthesis was estimated by measuring the amount of [3 H]‐thymidine incorporation into trichloroacetic acid (TCA) insoluble cell precipitates. The specific activity of alkaline phosphatase was assayed using p‐nitrophenylphosphate as a substrate. The ability of the cells to synthesize osteocalcin was investigated in serum‐free culture medium using the ELSA‐OST‐NAT immunoradiometric kit. After 3 h of culture, the percentage of cellular attachment did not differ significantly between specimens blasted with 180–300 μm particles and the turned specimens. All blasted surfaces showed significantly higher [3 H]‐thymidine incorporation than the turned surfaces (P<0.05), with the highest on the surfaces blasted with 180–300 μm particles. Osteocalcin synthesis by the cells in response to stimulation by 1,25(OH)2 D 3, was also significantly greater (P<0.05) on the surfaces blasted with TiO 2 particles. However, analysis of alkaline phosphatase activity disclosed no significant differences among the four surface modifications. It is concluded that in this cellular model, the proliferation and differentiation of cells derived from human mandibular bone is enhanced by surface roughness of the titanium implant. However, increasing the size of the blasting particles to 300 μm does not further increase the initial attachment of the cells compared to turned surfaces and those blasted with 63–90 μm particles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-0501.2001.120513.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 245

Metadata

Authors
Mustafa, K., Wroblewski, J., Lopez, B. S., Wennerberg, A., Hultenby, K., & Arvidson, K.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2001-10
Volume
12
Issue
5
Pages
515-525
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W2168784030
Cited by
245
References
0
FWCI
9.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determining optimal surface roughness of TiO2 blasted titanium implant material for attachment, proliferation and differentiation of cells derived from human mandibular alveolar bone. https://app.cochat.ai/papers/10.1034/j.1600-0501.2001.120513.x
The paper
Mustafa, K., Wroblewski, J., Lopez, B. S., Wennerberg, A., Hultenby, K., & Arvidson, K. (2001). Determining optimal surface roughness of TiO2 blasted titanium implant material for attachment, proliferation and differentiation of cells derived from human mandibular alveolar bone. Clinical Oral Implants Research. https://doi.org/10.1034/j.1600-0501.2001.120513.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.