The DOI matches its Crossref record.
Determining optimal surface roughness of TiO2 blasted titanium implant material for attachment, proliferation and differentiation of cells derived from human mandibular alveolar bone
Abstract
In the complex process of bone formation at the implant‐tissue interface, implant surface roughness is an important factor modulating osteoblastic function. In this study, primary cultures of osteoblast‐like cells, derived from human mandibular bone, were used. The aim was to examine the effect of varying surface roughness of titanium implant material on cellular attachment, proliferation and differentiation. A recognized method of increasing surface roughness and enlarging the surface area of titanium implants is by blasting with titanium dioxide particles: the four specimen types in the study comprised surfaces which were machine‐turned only, or blasted after turning, with 63–90 μm, 106–180 μm, or 180–300 μm TiO 2 particles, respectively. The specimens were analyzed by scanning electron microscopy and confocal laser scanning. The turned samples had the smoothest surfaces: average height deviation (S a) of 0.20 μm. The roughest were those blasted with 180–300 μm particles, S a value 1.38 μm. Blasting with intermediate particle sizes yielded S a values of 0.72 μm and 1.30 μm, respectively. Cell profile areas were measured using a semiautomatic interactive image analyzer. Figures were expressed as percentage of attachment. DNA synthesis was estimated by measuring the amount of [3 H]‐thymidine incorporation into trichloroacetic acid (TCA) insoluble cell precipitates. The specific activity of alkaline phosphatase was assayed using p‐nitrophenylphosphate as a substrate. The ability of the cells to synthesize osteocalcin was investigated in serum‐free culture medium using the ELSA‐OST‐NAT immunoradiometric kit. After 3 h of culture, the percentage of cellular attachment did not differ significantly between specimens blasted with 180–300 μm particles and the turned specimens. All blasted surfaces showed significantly higher [3 H]‐thymidine incorporation than the turned surfaces (P<0.05), with the highest on the surfaces blasted with 180–300 μm particles. Osteocalcin synthesis by the cells in response to stimulation by 1,25(OH)2 D 3, was also significantly greater (P<0.05) on the surfaces blasted with TiO 2 particles. However, analysis of alkaline phosphatase activity disclosed no significant differences among the four surface modifications. It is concluded that in this cellular model, the proliferation and differentiation of cells derived from human mandibular bone is enhanced by surface roughness of the titanium implant. However, increasing the size of the blasting particles to 300 μm does not further increase the initial attachment of the cells compared to turned surfaces and those blasted with 63–90 μm particles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effects of topography and composition of titanium surface oxides on osteoblast responses
Zhu, X., Chen, J., Scheideler, L., Reichl, R., & Geis-Gerstorfer, J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.011 · Cited by 534
Kunzler, T. P., Drobek, T., Schuler, M., & Spencer, N. D. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.019 · Cited by 518
Topography effects of pure titanium substrates on human osteoblast long-term adhesion
ANSELME, K., & BIGERELLE, M. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2004.11.009 · Cited by 314
Peri-implant osteogenesis in health and osteoporosis
Marco, F., Milena, F., Gianluca, G., & Vittoria, O. (2005) · Micron · doi:10.1016/j.micron.2005.07.008 · Cited by 304
Osteoblastic cell behaviour on different titanium implant surfaces
Le Guehennec, L., Lopez-Heredia, M.-A., Enkel, B., Weiss, P., Amouriq, Y., & Layrolle, P. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.12.002 · Cited by 293
Metadata
- Authors
- Mustafa, K., Wroblewski, J., Lopez, B. S., Wennerberg, A., Hultenby, K., & Arvidson, K.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2001-10
- Volume
- 12
- Issue
- 5
- Pages
- 515-525
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2168784030
- Cited by
- 245
- References
- 0
- FWCI
- 9.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determining optimal surface roughness of TiO2 blasted titanium implant material for attachment, proliferation and differentiation of cells derived from human mandibular alveolar bone. https://app.cochat.ai/papers/10.1034/j.1600-0501.2001.120513.x
- The paper
- Mustafa, K., Wroblewski, J., Lopez, B. S., Wennerberg, A., Hultenby, K., & Arvidson, K. (2001). Determining optimal surface roughness of TiO2 blasted titanium implant material for attachment, proliferation and differentiation of cells derived from human mandibular alveolar bone. Clinical Oral Implants Research. https://doi.org/10.1034/j.1600-0501.2001.120513.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.