Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 213

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Plaque formation on surface modified dental implants: An in vitro study

Größner‐Schreiber, Birte, Griepentrog, Michael, Haustein, Ingrun, Müller, Wolf‐Dieter, Briedigkeit, Helga, Göbel, Ulf Berthold, Lange, Klaus‐Peter·2001·Clinical Oral Implants Research

Abstract

Abstract: Bacterial adhesion on titanium implant surfaces has a strong influence on healing and long‐term outcome of dental implants. Parameters like surface roughness and chemical composition of the implant surface were found to have a significant impact on plaque formation. The purpose of this study was to evaluate the influence of two physical hard coatings on bacterial adhesion in comparison with control surfaces of equivalent roughness. Two members of the oral microflora, Streptococcus mutans and Streptococcus sanguis were used. Commercially pure titanium discs were modified using four different surface treatments: physical vapour deposition (PVD) with either titanium nitride (TiN) or zirconium nitride (ZrN), thermal oxidation and structuring with laser radiation. Polished titanium surfaces were used as controls. Surface topography was examined by SEM and estimation of surface roughness was done using a contact stylus profilometer. Contact angle measurements were carried out to calculate surface energy. Titanium discs were incubated in the respective bacterial cell suspension for one hour and single colonies formed by adhering bacteria were counted by fluorescence microscopy. Contact angle measurements showed no significant differences between the surface modifications. The surface roughness (R a) of all surfaces examined was between 0.14 and 1.00 μm. A significant reduction of the number of adherent bacteria was observed on inherently stable titanium hard materials such as TiN and ZrN and thermically oxidated titanium surfaces compared to polished titanium. In conclusion, physical modification of titanium implant surfaces such as coating with TiN or ZrN may reduce bacterial adherence and hence improve clinical results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-0501.2001.120601.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 213

Metadata

Authors
Größner‐Schreiber, B., Griepentrog, M., Haustein, I., Müller, W., Briedigkeit, H., Göbel, U. B., & Lange, K.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2001-12
Volume
12
Issue
6
Pages
543-551
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W2150735554
Cited by
213
References
1
FWCI
6.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Plaque formation on surface modified dental implants: An in vitro study. https://app.cochat.ai/papers/10.1034/j.1600-0501.2001.120601.x
The paper
Größner‐Schreiber, B., Griepentrog, M., Haustein, I., Müller, W., Briedigkeit, H., Göbel, U. B., & Lange, K. (2001). Plaque formation on surface modified dental implants: An in vitro study. Clinical Oral Implants Research. https://doi.org/10.1034/j.1600-0501.2001.120601.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.