Dental implant surfaces are important in determining the tissue/surface interaction. One of the first cells to adhere to the implant surface is the monocyte. This study examines the effect of surface roughness on monocyte adhesion and cytokine secretion. Monocyte adherence to titanium discs of 4 different degrees of surface roughness and plastic surfaces was assayed. Blood mononuclear cells were incubated for 1.5 h in 16 mm culture wells into which titanium discs had been placed. Non‐adherent cells were washed off and the numbers of remaining adherent monocyte determined by DNA quantification. TNF‐α and PGE 2 secretion in media from overnight cultures of attached monocytes stimulated with lipopolysaccharide (LPS) was quantified using ELISA and RIA, respectively. Monocyte adherence to rough titanium surfaces was greater than to turned titanium surfaces, while the lowest adherence was to the plastic surface. No significant differences in adherence to 250, 75 or 25 μm blasted surfaces could be detected. The number of adherent monocytes increased with time, with maximum adhesion after 2 h of incubation. Incubation of monocytes adherent to titanium surfaces resulted in a decrease of less than 30% in their numbers over 7 days, whereas cells attached to plastic surfaces decreased to non‐detectable numbers after 48 h. Porphyromonas gingivalis LPS stimulation upregulated TNF‐α and PGE 2 secretion into the media. The LPS‐induced TNF‐α and PGE 2 secretion was independent of the titanium surface roughness, however the lowest amounts of TNF‐α and PGE 2 were secreted from cells attached to plastic surfaces. The results of this study indicate that the number of monocytes attached to blasted titanium surfaces is significantly greater than to machined titanium surfaces. PGE 2 and TNF‐α secretion is less influenced by titanium surface roughness.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-0501.2002.130111.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 92

Metadata

Authors
Soskolne, W. A., Cohen, S., Shapira, L., Sennerby, L., & Wennerberg, A.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2002-02
Volume
13
Issue
1
Pages
86-93
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W2033423153
Cited by
92
References
1
FWCI
2.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effect of titanium surface roughness on the adhesion of monocytes and their secretion of TNF‐α and PGE2. https://app.cochat.ai/papers/10.1034/j.1600-0501.2002.130111.x
The paper
Soskolne, W. A., Cohen, S., Shapira, L., Sennerby, L., & Wennerberg, A. (2002). The effect of titanium surface roughness on the adhesion of monocytes and their secretion of TNF‐α and PGE2. Clinical Oral Implants Research. https://doi.org/10.1034/j.1600-0501.2002.130111.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.