CoChat

Thermal changes observed at implant sites during internal and external irrigation

Benington, Ian C., Biagioni, Paul A., Briggs, James, Sheridan, Sean, Lamey, Philip‐John · 2002 · Clinical Oral Implants Research
Cited by 171

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

In the preparation of osseointegrated dental implant sites, the use of bone drilling with conventional external irrigation has been shown to be thermally non‐injurious to bovine bone, when employed as a model for dental implantology. The use of internal irrigation drilling systems is promoted on the basis of improved delivery of coolant to the bone/drill interface, which should subsequently improve local debridement and cooling, and therefore reduce thermal insults to the bone. The aim of this bovine model study was to compare the temperatures that were generated with external and internal irrigation systems during bone preparation for dental implants. A constant drill load of 1.7 kg was applied throughout the drilling procedures via a drilling rig. The burs that were used for both irrigation methods were a 2 mm twist drill for cutting the channel and a 3.25 mm drill for trephining this channel. The principal recorded parameter was the change in temperature generated via the drilling procedure. The 2 mm twist drills produced a maximum change in temperature of only 3.0°C and 3.1°C for the internal and external irrigation systems, respectively. Maximum changes for the 3.25 mm drills were 1.34°C and 1.62°C, respectively. Using the t‐test, no statistical benefit was observed for one irrigant delivery system over the other. The clinical benefit of using the more expensive internal irrigation systems is therefore deemed unjustifiable, on the grounds that these systems do not appear to reduce the thermal challenge to the bone over and above that of simple flood irrigation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-0501.2002.130309.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 171

Metadata

Authors
Benington, I. C., Biagioni, P. A., Briggs, J., Sheridan, S., & Lamey, P.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2002-05-12
Volume
13
Issue
3
Pages
293-297
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W1992054770
Cited by
171
References
3
FWCI
2.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Thermal changes observed at implant sites during internal and external irrigation. https://app.cochat.ai/papers/10.1034/j.1600-0501.2002.130309.x
The paper
Benington, I. C., Biagioni, P. A., Briggs, J., Sheridan, S., & Lamey, P. (2002). Thermal changes observed at implant sites during internal and external irrigation. Clinical Oral Implants Research. https://doi.org/10.1034/j.1600-0501.2002.130309.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.