Comparison of periodontal pocket penetration by conventional and microultrasonic inserts
Open accessThe DOI matches its Crossref record.
Abstract
Recently, 'microultrasonic' instruments have been developed with the aim of improving root‐surface debridement. Whilst their reduced tip diameter and modified shape suggests that they may penetrate the periodontal pocket more easily than conventional inserts, there have been few studies investigating their efficacy. The aim of this investigation was therefore to compare the periodontal pocket penetration of a conventional ultrasonic insert (P10 insert – Dentsply) with microultrasonic inserts (Slimline FSI left and right – Dentsply). Efficacy of penetration was assessed by a modification of instrument limit. This modification permitted measurement of the linear % removal of the apical plaque border by image analysis. Debridement was carried out on randomly allocated surfaces of 30 teeth which had been treatment planned for extraction due to periodontitis. One surface on each tooth acted as an untreated control. The results of this study showed that both types of insert were able to reach and debride the apical plaque border, and at all pocket depths assessed. However no significant differences were found between the Slimline insert and the P10 tip. Trends between instruments were observed which suggest that the Slimline insert might more easily penetrate to and debride the apical plaque border in deep pockets, whereas the P10 insert might be more effective in disrupting the apical plaque border in shallow pockets. Future investigations using a larger sample size will be needed to confirm these observations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cobb, C. M. (2002) · Journal of Clinical Periodontology · doi:10.1034/j.1600-051x.29.s2.4.x · Cited by 566
Nonsurgical periodontal therapy
Drisko, C. H. (2001) · Periodontology 2000 · doi:10.1034/j.1600-0757.2001.22250106.x · Cited by 356
Effects of nonsurgical periodontal therapy on hard and soft tissues
Adriaens, P. A., & Adriaens, L. M. (2004) · Periodontology 2000 · doi:10.1111/j.1600-0757.2004.03676.x · Cited by 221
Wennström, J. L., Tomasi, C., Bertelle, A., & Dellasega, E. (2005) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.2005.00776.x · Cited by 214
Antimicrobial effects of mechanical debridement
PETERSILKA, G. J., EHMKE, B., & FLEMMIG, T. F. (2002) · Periodontology 2000 · doi:10.1034/j.1600-0757.2002.280103.x · Cited by 210
Metadata
- Authors
- Clifford, L. R., Needleman, I. G., & Chan, Y. K.
- Venue
- Journal of Clinical Periodontology
- Publisher
- Wiley
- Published
- 1999-02
- Volume
- 26
- Issue
- 2
- Pages
- 124-130
- ISSN
- 0303-6979 (ISSN-L)
- 1600-051X
- OpenAlex
- W2031928999
- Cited by
- 35
- References
- 0
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of periodontal pocket penetration by conventional and microultrasonic inserts. https://app.cochat.ai/papers/10.1034/j.1600-051x.1999.260210.x
- The paper
- Clifford, L. R., Needleman, I. G., & Chan, Y. K. (1999). Comparison of periodontal pocket penetration by conventional and microultrasonic inserts. Journal of Clinical Periodontology. https://doi.org/10.1034/j.1600-051x.1999.260210.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.