CoChat

Comparison of periodontal pocket penetration by conventional and microultrasonic inserts

Open access
Clifford, Lester R., Needleman, Ian G., Chan, Yoong Kian · 1999 · Journal of Clinical Periodontology
Cited by 35

The DOI matches its Crossref record.

Abstract

Recently, 'microultrasonic' instruments have been developed with the aim of improving root‐surface debridement. Whilst their reduced tip diameter and modified shape suggests that they may penetrate the periodontal pocket more easily than conventional inserts, there have been few studies investigating their efficacy. The aim of this investigation was therefore to compare the periodontal pocket penetration of a conventional ultrasonic insert (P10 insert – Dentsply) with microultrasonic inserts (Slimline FSI left and right – Dentsply). Efficacy of penetration was assessed by a modification of instrument limit. This modification permitted measurement of the linear % removal of the apical plaque border by image analysis. Debridement was carried out on randomly allocated surfaces of 30 teeth which had been treatment planned for extraction due to periodontitis. One surface on each tooth acted as an untreated control. The results of this study showed that both types of insert were able to reach and debride the apical plaque border, and at all pocket depths assessed. However no significant differences were found between the Slimline insert and the P10 tip. Trends between instruments were observed which suggest that the Slimline insert might more easily penetrate to and debride the apical plaque border in deep pockets, whereas the P10 insert might be more effective in disrupting the apical plaque border in shallow pockets. Future investigations using a larger sample size will be needed to confirm these observations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-051x.1999.260210.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 35

Metadata

Authors
Clifford, L. R., Needleman, I. G., & Chan, Y. K.
Venue
Journal of Clinical Periodontology
Publisher
Wiley
Published
1999-02
Volume
26
Issue
2
Pages
124-130
ISSN
  • 0303-6979 (ISSN-L)
  • 1600-051X
OpenAlex
W2031928999
Cited by
35
References
0
FWCI
2.35
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of periodontal pocket penetration by conventional and microultrasonic inserts. https://app.cochat.ai/papers/10.1034/j.1600-051x.1999.260210.x
The paper
Clifford, L. R., Needleman, I. G., & Chan, Y. K. (1999). Comparison of periodontal pocket penetration by conventional and microultrasonic inserts. Journal of Clinical Periodontology. https://doi.org/10.1034/j.1600-051x.1999.260210.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.