Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 176

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Desensitizing effects of an Er:YAG laser on hypersensitive dentine: A controlled, prospective clinical study

Schwarz, Frank, Arweiler, Nicole, Georg, Thomas, Reich, Elmar · 2002 · Journal of Clinical Periodontology

Abstract

Aim: The aim of the present study was to evaluate and compare the desensitizing effects of an Er:YAG laser (KEY II®, KaVo, Germany) and Dentin Protector® (Vivadent, Germany) on cervically exposed hypersensitive dentine. Method: A group of 30 patients showing a total of 104 contralateral pairs of hypersensitive and caries‐free teeth was selected and randomly allocated in a split‐mouth design to either (1) Er:YAG laser (80 mJ/pulse, 3 Hz), or (2) the application of Dentin Protector® (polyurethane‐isocyanate 22.5%; methylenechloride 77.5%) whereat one pair served as an untreated control in each patient. The degree of sensitivity to a thermal stimulus was determined qualitatively with an evaporative stimulus defined as a 3‐s air blast at a distance of 2 mm from each site to be tested. A qualitative registration of the degree of discomfort was determined according to an arbitrary pain scale in 4 degrees. Recordings were assessed before treatment, immediately after, 1 week, 2 and 6 months after treatment by 1 blinded examiner. Results: Both treatment forms resulted in significant improvements of discomfort immediately after and 1 week post treatment. After 2 months, the discomfort in the Dentin Protector® group increased up to 65% of the baseline score and even up to 90% after 6 months, whereas the effect of the laser remained at the same level that was achieved immediately after treatment. The differences immediately after, 1 week, 2 and 6 months post treatment between both groups were statistically high significant (p 0.001; respectively). Compared to the untreated control group, both treatment forms resulted in a significant reduction of discomfort at each follow‐up examination. Conclusion: It was concluded that desensitizing of hypersensitive dentine with an Er:YAG laser is effective and the maintenance of the positive result was more prolonged than with Dentin Protector®.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-051x.2002.290305.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 176

Metadata

Authors
Schwarz, F., Arweiler, N., Georg, T., & Reich, E.
Venue
Journal of Clinical Periodontology
Publisher
Wiley
Published
2002-03
Volume
29
Issue
3
Pages
211-215
ISSN
  • 0303-6979 (ISSN-L)
  • 1600-051X
OpenAlex
W1595528682
Cited by
176
References
1
FWCI
5.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Desensitizing effects of an Er:YAG laser on hypersensitive dentine: A controlled, prospective clinical study. https://app.cochat.ai/papers/10.1034/j.1600-051x.2002.290305.x
The paper
Schwarz, F., Arweiler, N., Georg, T., & Reich, E. (2002). Desensitizing effects of an Er:YAG laser on hypersensitive dentine: A controlled, prospective clinical study. Journal of Clinical Periodontology. https://doi.org/10.1034/j.1600-051x.2002.290305.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.