The DOI matches its Crossref record.
Optical tweezers for measuring red blood cell elasticity: application to the study of drug response in sickle cell disease
Abstract
Abstract: The deformability of erythrocytes is a critical determinant of blood flow in microcirculation. By capturing red blood cells (RBC) with optical tweezers and dragging them through a viscous fluid we were able to measure their overall elasticity. We measured, and compared, the RBC deformability of 15 homozygous patients (HbSS) including five patients taking hydroxyurea (HU) for at least 6 months (HbSS/HU), 10 subjects with sickle cell trait (HbAS) and 35 normal controls. Our results showed that the RBC deformability was significantly lower in haemoglobin S (HbS) subjects (HbSS and HbAS), except for HbSS/HU cells, whose deformability was similar to the normal controls. Our data showed that the laser optical tweezers technique is able to detect differences in HbS RBC from subjects taking HU, and to differentiate RBC from normal controls and HbAS, indicating that this is a very sensitive method and can be applied for detection of drug‐response in sickle cell disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomechanics approaches to studying human diseases
Lee, G. Y. H., & Lim, C. T. (2007) · Trends in Biotechnology · doi:10.1016/j.tibtech.2007.01.005 · Cited by 485
Biomechanical properties of red blood cells in health and disease towards microfluidics
Tomaiuolo, G. (2014) · Biomicrofluidics · doi:10.1063/1.4895755 · Cited by 368
Barabino, G. A., Platt, M. O., & Kaul, D. K. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105339 · Cited by 311
Tsai, M., Kita, A., Leach, J., Rounsevell, R., Huang, J. N., Moake, J., Ware, R. E., Fletcher, D. A., & Lam, W. A. (2012) · Journal of Clinical Investigation · doi:10.1172/jci58753 · Cited by 297
Optical coherence elastography for tissue characterization: a review
Wang, S., & Larin, K. V. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201400108 · Cited by 270
Metadata
- Authors
- Brandão, M. M., Fontes, A., Barjas‐Castro, M. L., Barbosa, L. C., Costa, F. F., Cesar, C. L., & Saad, S. T. O.
- Venue
- European Journal of Haematology
- Publisher
- Wiley
- Published
- 2003-03-26
- Volume
- 70
- Issue
- 4
- Pages
- 207-211
- ISSN
- 0902-4441 (ISSN-L)
- 1600-0609
- OpenAlex
- W2039888550
- Cited by
- 250
- References
- 0
- FWCI
- 2.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical tweezers for measuring red blood cell elasticity: application to the study of drug response in sickle cell disease. https://app.cochat.ai/papers/10.1034/j.1600-0609.2003.00027.x
- The paper
- Brandão, M. M., Fontes, A., Barjas‐Castro, M. L., Barbosa, L. C., Costa, F. F., Cesar, C. L., & Saad, S. T. O. (2003). Optical tweezers for measuring red blood cell elasticity: application to the study of drug response in sickle cell disease. European Journal of Haematology. https://doi.org/10.1034/j.1600-0609.2003.00027.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.