CoChat

Scrotal temperatures do not differ among young boys wearing disposable or reusable diapers

Grove, G. L., Grove, M. J., Bates, N. T., Wagman, L. M., Leyden, J. J. · 2002 · Skin Research and Technology
Cited by 8

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background/aims: This study investigated the effect of specific, commonly used diaper types on scrotal temperatures in normal healthy, young boys. These included both modern disposable and reusable diapers as well as various types of protective outer coverings that are in common use in both North America and Europe Methods: Scrotal and skin surface temperatures were continuously monitored in healthy, young males using a computerized data‐logging system based on temperature probes specifically designed for paediatric studies. These systems could be used either tethered to the PC or made completely portable depending upon the age and activity of the child being measured. Based on our results from several pilot studies, it became clear that the best way to determine if disposable and reusable diapers differ with regard to their impact on scrotal temperatures is to run these comparisons under controlled laboratory conditions where ‘diaper type’ was the primary variable. A 2‐h time period was chosen to ensure that sufficient time had elapsed for thermal equilibrium to be established under the diapers. We also felt it necessary to study the impact of urination and simulated this condition over the last 15 min using standardized methods. In addition to the skin surface temperatures, we also measured the temperature of the tympanic membrane using an infrared thermometer as an estimate of ‘core’ temperature for each individual at various times during the session. Results and Conclusions: In this study, we have clearly shown that scrotal temperatures are the same whether the child is wearing disposable or reusable cloth diapers with a protective cover. The only situation in which scrotal temperatures were found to be lower is when the cloth diaper is used alone without a protective cover but this is not representative of how these products are actually used. We also found that on average scrotal temperatures are significantly lower than core for each diaper type. Occasionally, we did see individuals in which the maximal scrotal temperatures approached core temperatures but in every case the thermal sensors were soiled by a bowel movement. We also found that skin surface temperatures increased not only when covered by a diaper but also due to the thermal insulation provided by outer garments and blankets.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-0846.2002.00336.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 13

  1. 10.1016/S0015-0282(16)53832-1 · DOI · Paper page
  2. Magdesburg H., 1986, Thermological Methods Weinheim: Verlag Chemie, 203
  3. 10.1177/000992289103000420 · doi:10.1177/000992289103000420
  4. ASTM E., 2000, Annual Book of ASTM Standards, 589
  5. 10.1159/000060561 · doi:10.1159/000060561
  6. 10.1113/jphysiol.1980.sp013245 · DOI
  7. Talbot FB., 1931, Skin Temperatures of Children, Am J Dis Children, 42, 965
  8. 10.1136/adc.69.2.181 · doi:10.1136/adc.69.2.181
  9. 10.1136/adc.64.4.596 · doi:10.1136/adc.64.4.596
  10. 10.1542/peds.94.5.669 · DOI
  11. 10.1136/adc.66.7_Spec_No.783 · doi:10.1136/adc.66.7_spec_no.783
  12. Wong DL, 1992, Diapering choices: a critical review of the issues, Pediatri Nurs, 18, 41
  13. 10.1046/j.1440-1754.1999.00374.x · DOI

Cited by

Metadata

Authors
Grove, G. L., Grove, M. J., Bates, N. T., Wagman, L. M., & Leyden, J. J.
Venue
Skin Research and Technology
Publisher
Wiley
Published
2002-11
Volume
8
Issue
4
Pages
260-270
ISSN
  • 0909-752X
  • 1600-0846
Cited by
8
References
1
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.