Comfort and discomfort of dental trauma splints – a comparison of a new device (TTS) with three commonly used splinting techniques
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The present experimental study compared four dental trauma splints in 10 volunteers. The evaluated splints included a wire‐composite splint (WCS), a button‐bracket splint (BS), a resin splint (RS), and the newly developed titanium trauma splint (TTS). All splints were bonded to the labial surfaces of the maxillary lateral and central incisors and left in place for 1 week. After splint removal, the next splint was placed after a 1‐week rest period. The sequence of splint application was randomized for each individual. The following subjective parameters were assessed using a visual analogue scale: sensitiveness of splinted teeth, irritation of the gingival margin, irritation of the lips, impairment of speech, eating and oral hygiene. The results show that the application of BS leads to a significantly higher irritation of the lips and greater impairment of speech compared to other splints (P < 0.05). The RS leads to an increased and significantly higher irritation of the gingiva (P < 0.05) owing to a significant increase in cleaning difficulties (P < 0.05). In conclusion, WCS and TTS appear to be more accepted splints according to a subjective assessment by 10 volunteers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rigidity of various fixation methods used as dental splints
Oikarinen, K., Andreasen, J. O., & Andreasen, F. M. (1992) · Dental Traumatology · doi:10.1111/j.1600-9657.1992.tb00447.x · Cited by 68
Cited by
DiAngelis, A. J., Andreasen, J. O., Ebeleseder, K. A., Kenny, D. J., Trope, M., Sigurdsson, A., Andersson, L., Bourguignon, C., Flores, M. T., Hicks, M. L., et al. (2012) · Dental Traumatology · doi:10.1111/j.1600-9657.2011.01103.x · Cited by 597
Guidelines for the management of traumatic dental injuries. II. Avulsion of permanent teeth
Flores, M. T., Andersson, L., Andreasen, J. O., Bakland, L. K., Malmgren, B., Barnett, F., Bourguignon, C., DiAngelis, A., Hicks, L., Sigurdsson, A., et al. (2007) · Dental Traumatology · doi:10.1111/j.1600-9657.2007.00605.x · Cited by 421
Self-citationFlores, M. T., Andersson, L., Andreasen, J. O., Bakland, L. K., Malmgren, B., Barnett, F., Bourguignon, C., DiAngelis, A., Hicks, L., Sigurdsson, A., et al. (2007) · Dental Traumatology · doi:10.1111/j.1600-9657.2007.00592.x · Cited by 351
Kwan, S. C., Johnson, J. D., & Cohenca, N. (2012) · Dental Traumatology · doi:10.1111/j.1600-9657.2011.01086.x · Cited by 67
Metadata
- Authors
- Filippi, A., Von Arx, T., & Lussi, A.
- Venue
- Dental Traumatology
- Publisher
- Wiley
- Published
- 2002-10
- Volume
- 18
- Issue
- 5
- Pages
- 275-280
- ISSN
- 1600-4469 (ISSN-L)
- 1600-9657
- OpenAlex
- W2054987908
- Cited by
- 54
- References
- 1
- FWCI
- 0.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.