The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Maskless fabrication of light-directed oligonucleotide microarrays using a digital micromirror array
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light-Directed, Spatially Addressable Parallel Chemical Synthesis
Fodor, S. P. A., Read, J. L., Pirrung, M. C., Stryer, L., Lu, A. T., & Solas, D. (1991) · Science · doi:10.1126/science.1990438 · Cited by 2,696
Light-generated oligonucleotide arrays for rapid DNA sequence analysis.
Pease, A. C., Solas, D., Sullivan, E. J., Cronin, M. T., Holmes, C. P., & Fodor, S. P. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.11.5022 · Cited by 1,367
The Efficiency of Light-Directed Synthesis of DNA Arrays on Glass Substrates
McGall, G. H., Barone, A. D., Diggelmann, M., Fodor, S. P. A., Gentalen, E., & Ngo, N. (1997) · Journal of the American Chemical Society · doi:10.1021/ja964427a · Cited by 282
Research works printed but not linked: 6
- Sampsell, J.B. Digital micromirror device and its application to projection displays. J. Vac. Sci. Technol. B12, 3242–3246 (1994). · doi:10.1116/1.587506
- Welford, W.T. Useful optics (University of Chicago Press, Chicago; 1991).
- Cadet, J. & Vigny, P. The photochemistry of nucleic acids. In Bioorganic photochemistry: photochemistry and the nucleic acids (ed. Morrison, H.) 1–237 (Wiley, New York; 1990).
- Offner, A. New concepts in projection mask aligners. Optical Engineering 14, 130–132 (1975). · doi:10.1117/12.7978742
- Smith, W.J. Modern optical engineering 345–361 (McGraw-Hill, New York; 1990).
- Gove, R.J. et al. High definition display system based on digital micromirror device. Texas Instruments White Paper (1997).
Cited by
Sequencing technologies – the next generation
Metzker, M. L. (2010) · Nature Reviews Genetics · doi:10.1038/nrg2626 · Cited by 7,066
Expression profiling using microarrays fabricated by an ink-jet oligonucleotide synthesizer
Hughes, T. R., Mao, M., Jones, A. R., Burchard, J., Marton, M. J., Shannon, K. W., Lefkowitz, S. M., Ziman, M., Schelter, J. M., Meyer, M. R., et al. (2001) · Nature Biotechnology · doi:10.1038/86730 · Cited by 1,298
DNA Biosensors and Microarrays
Sassolas, A., Leca-Bouvier, B. D., & Blum, L. J. (2008) · Chemical Reviews · doi:10.1021/cr0684467 · Cited by 1,246
Advanced methods of plant disease detection. A review
Martinelli, F., Scalenghe, R., Davino, S., Panno, S., Scuderi, G., Ruisi, P., Villa, P., Stroppiana, D., Boschetti, M., Goulart, L. R., et al. (2015) · Agronomy for Sustainable Development · doi:10.1007/s13593-014-0246-1 · Cited by 964
A high-resolution map of active promoters in the human genome
Kim, T. H., Barrera, L. O., Zheng, M., Qu, C., Singer, M. A., Richmond, T. A., Wu, Y., Green, R. D., & Ren, B. (2005) · Nature · doi:10.1038/nature03877 · Cited by 938
Self-citation
Metadata
- Authors
- Singh-Gasson, S., Green, R. D., Yue, Y., Nelson, C., Blattner, F., Sussman, M. R., & Cerrina, F.
- Venue
- Nature Biotechnology
- Published
- 1999-10
- Volume
- 17
- Issue
- 10
- Pages
- 974-978
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W1542309476
- Cited by
- 733
- References
- 3
- FWCI
- 9.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Maskless fabrication of light-directed oligonucleotide microarrays using a digital micromirror array. https://app.cochat.ai/papers/10.1038/13664
- The paper
- Singh-Gasson, S., Green, R. D., Yue, Y., Nelson, C., Blattner, F., Sussman, M. R., & Cerrina, F. (1999). Maskless fabrication of light-directed oligonucleotide microarrays using a digital micromirror array. Nature Biotechnology. https://doi.org/10.1038/13664
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.