Single kinesin molecules studied with a molecular force clamp
Abstract
Kinesin is a two-headed, ATP-driven motor protein that moves processively along microtubules in discrete steps of 8 nm, probably by advancing each of its heads alternately in sequence. Molecular details of how the chemical energy stored in ATP is coupled to mechanical displacement remain obscure. To shed light on this question, a force clamp was constructed, based on a feedback-driven optical trap capable of maintaining constant loads on single kinesin motors. The instrument provides unprecedented resolution of molecular motion and permits mechanochemical studies under controlled external loads. Analysis of records of kinesin motion under variable ATP concentrations and loads revealed several new features. First, kinesin stepping appears to be tightly coupled to ATP hydrolysis over a wide range of forces, with a single hydrolysis per 8-nm mechanical advance. Second, the kinesin stall force depends on the ATP concentration. Third, increased loads reduce the maximum velocity as expected, but also raise the apparent Michaelis-Menten constant. The kinesin cycle therefore contains at least one load-dependent transition affecting the rate at which ATP molecules bind and subsequently commit to hydrolysis. It is likely that at least one other load-dependent rate exists, affecting turnover number. Together, these findings will necessitate revisions to our understanding of how kinesin motors function.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Members of the kinesin family of molecular motors are capable of taking over 100 steps on their microtubule track without dissociating.
“Members of the kinesin family of molecular motors are capable of taking over 100 steps on their microtubule track without dissociating”
From Stepping and Stretching (2003) · cites this paper as [6]
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 31 · Cited by 1,027
- Authors
- Visscher, K., Schnitzer, M. J., & Block, S. M.
- Affiliations
- Princeton University (US)
- Corresponding author
- Schnitzer, Mark J.
- Venue
- Nature
- Published
- 1999-07
- Volume
- 400
- Issue
- 6740
- Pages
- 184-189
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W1487659884
- Cited by
- 1,027
- References
- 31
- Citations by year
- 2026: 16 · 2025: 28 · 2024: 24 · 2023: 18 · 2022: 24 · 2021: 38 · 2020: 19 · 2019: 36 · 2018: 35 · 2017: 59 · 2016: 37 · 2015: 41 · 2014: 34 · 2013: 43 · 2012: 43
- FWCI
- 11.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Microtubule and mitosis dynamics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Keywords
- kinesin, optical tweezers, ATP hydrolysis, chemo-mechanical coupling, microtubule motility, stall force, Michaelis-Menten constant, turnover number, single-molecule mechanics, motor protein mechanics
- MeSH terms
- Adenosine Triphosphate, Biomechanical Phenomena, Hydrolysis, Lasers, Microspheres, Kinesins, Molecular Motor Proteins
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.