Wireless capsule endoscopy
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although considerable progress has been made in energy storage technologies, batteries remain a major obstacle to miniaturization (2, 3) because their lifetimes are limited and highly constrained by the available volume, requiring periodic surgical replacement once the unit is depleted.”
From Wireless power transfer to deep-tissue microimplants (2014) · cites this paper as [2]
Citations
Cites
Active pixel sensors: are CCDs dinosaurs?
Fossum, E. R. (1993) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.148585 · Cited by 480
A Flexible Fibrescope, using Static Scanning
HOPKINS, H. H., & KAPANY, N. S. (1954) · Nature · doi:10.1038/173039b0 · Cited by 370
MACKAY, R. S., & JACOBSON, B. (1957) · Nature · doi:10.1038/1791239a0 · Cited by 207
Die Endoradiosonde - zur elektrischen pH-Messung im Magen und ihre klinische Bedeutung
Nöller, H. G. (1960) · DMW - Deutsche Medizinische Wochenschrift · doi:10.1055/s-0028-1112642 · Cited by 33
Research works printed but not linked: 1
- Zworkin, V. K. Nature 179, 898 (1957).
Cited by
Items 801–900 of 1,001
Best candidates for capsule endoscopy for obscure gastrointestinal bleeding
Ge, Z., Chen, H., Gao, Y., Hu, Y., & Xiao, S. (2006) · Journal of Gastroenterology and Hepatology · doi:10.1111/j.1440-1746.2006.04724.x · Cited by 32
Push Enteroscopy in the Era of Capsule Endoscopy
Sidhu, R., McAlindon, M. E., Kapur, K. C., Hurlstone, D. P., Wheeldon, M. C., & Sanders, D. S. (2008) · Journal of Clinical Gastroenterology · doi:10.1097/01.mcg.0000225655.85060.74 · Cited by 32
M2A Wireless Capsule Endoscopy for Diagnosing Ulcerative Jejunoileitis Complicating Celiac Disease
Apostolopoulos, P., Alexandrakis, G., Giannakoulopoulou, E., Kalantzis, C., Papanikolaou, I., Markoglou, C., & Kalantzis, N. (2004) · Endoscopy · doi:10.1055/s-2004-814259 · Cited by 32
Xie, X., Li, G. L., & Wang, Z. H. (2006) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2007/82160 · Cited by 32
Menciassi, A., Stefanini, C., Gorini, S., Pernorio, G., Dario, P., Kim, B., & Park, J. O. (2005) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2004.1389473 · Cited by 32
Occult and obscure gastrointestinal bleeding: Causes and diagnostic approach in 2009
Bresci, G. (2009) · World Journal of Gastrointestinal Endoscopy · doi:10.4253/wjge.v1.i1.3 · Cited by 32
Dhali, A., Kipkorir, V., Maity, R., Srichawla, B. S., Biswas, J., Rathna, R. B., Bharadwaj, H. R., Ongidi, I. H., Chaudhry, T., Morara, G., et al. (2025) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.16931 · Cited by 31
Caunedo-Álvarez, A., Gómez-Rodríguez, B. J., Romero-Vázquez, J., Argüelles‐Arias, F., Romero-Castro, R., Jm, G. M., Pellicer-Bautista, F., & Herrerías‐Gutiérrez, J. M. (2010) · Revista Española de Enfermedades Digestivas · doi:10.4321/s1130-01082010000200002 · Cited by 31
Design of a video capsule endoscopy system with low-power ASIC for monitoring gastrointestinal tract
Liu, G., Yan, G., Zhu, B., & Li, L. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1472-2 · Cited by 31
Lin, X.-L., Shi, Y., Cao, Y., Tan, X., Zeng, Y., Luo, S.-T., Li, Y., Li, Q., Xia, B., Fu, R.-G., et al. (2022) · Frontiers in Pharmacology · doi:10.3389/fphar.2022.960140 · Cited by 31
Noor, M. N., Nazir, M., Khan, S. A., Ashraf, I., & Song, O.-Y. (2023) · Applied Sciences · doi:10.3390/app13159031 · Cited by 31
Image Enhancement Using Geometric Mean Filter and Gamma Correction for WCE Images
Suman, S., Hussin, F. A., Malik, A. S., Walter, N., Goh, K., Hilmi, I. N., & Ho, S. H. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-12643-2_34 · Cited by 31
Low-complexity colour-space for capsule endoscopy image compression
Khan, T. H., & Wahid, K. A. (2011) · Electronics Letters · doi:10.1049/el.2011.2211 · Cited by 31
Automatic bleeding detection in wireless capsule endoscopy based on RGB pixel intensity ratio
Ghosh, T., Fattah, S. A., & Wahid, K. A. (2014) · International Conference on Electrical Engineering and Information Communication Technology · doi:10.1109/iceeict.2014.6919173 · Cited by 31
Capsule endoscope localization based on visual features
Iakovidis, D. K., Spyrou, E., Diamantis, D. E., & Tsiompanidis, I. (2013) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe.2013.6701570 · Cited by 31
Design of Endoscopic Capsule With Multiple Cameras
Gu, Y., Xie, X., Li, G., Sun, T., Wang, D., Yin, Z., Zhang, P., & Wang, Z. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2359012 · Cited by 31
Small bowel enteroscopy: territory conquered, future horizons
Semrad, C. E. (2009) · Current Opinion in Gastroenterology · doi:10.1097/mog.0b013e3283260916 · Cited by 31
Outcome of patients who have undergone total enteroscopy for obscure gastrointestinal bleeding
Shishido, T., Oka, S., Tanaka, S., Imagawa, H., Takemura, Y., Yoshida, S., & Chayama, K. (2012) · World Journal of Gastroenterology · doi:10.3748/wjg.v18.i7.666 · Cited by 31
The Current Main Types of Capsule Endoscopy
Li, Z., Carter, D., Eliakim, R., Zou, W., Wu, H., Liao, Z., Gong, Z., Wang, J., Chung, J. W., Song, S. Y., et al. (2014) · Springer eBooks · doi:10.1007/978-94-017-9229-5_2 · Cited by 31
Autonomous locomotion of capsule endoscope in gastrointestinal tract
Yang, S., Park, K., Kim, J., Kim, T. S., Cho, I., & Yoon, E.-S. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091642 · Cited by 31
A low power CMOS image sensor design for wireless endoscopy capsule
Zhang, M., Bermak, A., Li, X., & Wang, Z. (2008) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2008.4696958 · Cited by 31
Informative and Uninformative Regions Detection in WCE Frames
Maghsoudi, O. H., Talebpour, A., Sotanian-Zadeh, H., Alizadeh, M., & Soleimani, H. A. (2014) · Journal of advanced computing · doi:10.7726/jac.2014.1002a · Cited by 30
Review article: a practical approach to the clinical management of NSAID enteropathy
Srinivasan, A. R., & Cruz, P. P. D. (2017) · Scandinavian Journal of Gastroenterology · doi:10.1080/00365521.2017.1335769 · Cited by 30
Self-Propelled Colonoscopy Robot Using Flexible Paddles
Osawa, K., Nakadate, R., Arata, J., Nagao, Y., Akahoshi, T., Eto, M., & Hashizume, M. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.3017476 · Cited by 30
An Ingestible Electronics for Continuous and Real-Time Intraabdominal Pressure Monitoring
Liao, C., Cheng, C., Chen, C.-C., Jow, U.-M., Chen, C., Lai, Y.-L., Chen, Y.-C., & Ho, D. (2020) · Journal of Personalized Medicine · doi:10.3390/jpm11010012 · Cited by 30
Thermoresponsive Gelatin/Chitosan Hydrogel Films for a Degradable Capacitor
Fukada, K., Tajima, T., & Seyama, M. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c14905 · Cited by 30
Tamilarasan, A. G., Tran, Y., Paramsothy, S., & Leong, R. W. L. (2022) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.16007 · Cited by 30
Machine learning based small bowel video capsule endoscopy analysis: Challenges and opportunities
Wahab, H., Mehmood, I., Ugail, H., Sangaiah, A. K., & Muhammad, K. (2023) · Future Generation Computer Systems · doi:10.1016/j.future.2023.01.011 · Cited by 30
Kobayashi, Y., Watabe, H., Yamada, A., Hirata, Y., Yamaji, Y., Yoshida, H., & Koike, K. (2012) · Journal of Digestive Diseases · doi:10.1111/j.1751-2980.2012.00641.x · Cited by 30
Magnetically actuated and guided milli-gripper for medical applications
Mathis-Ullrich, F., Dheman, K., Schuerle, S., & Nelson, B. J. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139424 · Cited by 30
Automatic bleeding frame detection in the wireless capsule endoscopy images
Yuan, Y., & Meng, M. Q. ‐. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139360 · Cited by 30
Stopping mechanism for capsule endoscope using electrical stimulus
Woo, S. H., Kim, T. W., & Cho, J. H. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0553-x · Cited by 30
Hierarchical key frames extraction for WCE video
Yuan, Y., & Meng, M. Q. ‐. (2013) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2013.6617922 · Cited by 30
Lidums, I., Teo, E., Field, J. B. J., & Cummins, A. G. (2011) · Clinical and Translational Gastroenterology · doi:10.1038/ctg.2011.3 · Cited by 30
Crohnʼs Jejunoileitis: The Pediatricianʼs Perspective on Diagnosis and Management
Cuffari, C., Dubinsky, M. C., Darbari, A., Sena, L. M., & Baldassano, R. N. (2005) · Inflammatory Bowel Diseases · doi:10.1097/01.mib.0000166933.74477.69 · Cited by 30
Small intestine capsule endoscopy in magnetic suspended axial left ventricular assist device patient
Garatti, A., Bruschi, G., Girelli, C. M., & Vitali, E. (2005) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1510/icvts.2005.116871 · Cited by 30
A Novel Algorithm for Color Similarity Measurement and the Application for Bleeding Detection in WCE
Guobing, P. A. N., Fang, X. U., & Chen, J. (2011) · International Journal of Image Graphics and Signal Processing · doi:10.5815/ijigsp.2011.05.01 · Cited by 30
Component based design of a drug delivery capsule robot
Beccani, M., Aiello, G., Gkotsis, N., Tunc, H., Taddese, A. Z., Susilo, E., Völgyesi, P., Lédeczi, Á., Momi, E. D., & Valdastri, P. (2016) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2016.04.035 · Cited by 30
Development of a Tracking Algorithm for an In-Vivo RF Capsule Prototype
Shah, T., Aziz, S. M., & Vaithianathan, T. (2006) · International Conference on Electrical and Computer Engineering (ICECE) · doi:10.1109/icece.2006.355318 · Cited by 30
A Smart Capsule System for Automated Detection of Intestinal Bleeding Using HSL Color Recognition
Qiao, P., Liu, H., Yan, X., Jia, Z., & Pi, X. (2016) · PLoS ONE · doi:10.1371/journal.pone.0166488 · Cited by 30
Near-lossless energy-efficient image compression algorithm for wireless capsule endoscopy
Turcza, P., & Duplaga, M. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.04.006 · Cited by 30
Ballistic and snake photon imaging for locating optical endomicroscopy fibres
Tanner, M. G., Choudhary, T. R., Craven, T. H., Mills, B., Bradley, M., Henderson, R. K., Dhaliwal, K., & Thomson, R. R. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.004077 · Cited by 30
Conformal antennas for miniature in-body devices: The quest to improve radiation performance
Nikolayev, D., Zhadobov, M., Karban, P., & Sauleau, R. (2017) · URSI Radio Science Bulletin · doi:10.23919/ursirsb.2017.8409427 · Cited by 30
Usui∥, S., Hosoe, N., Matsuoka, K., Kobayashi, T., Nakano, M., Naganuma, M., Ishibashi∥, Y., Kimura, K., Yoneno∥, K., Kashiwagi, K., et al. (2014) · Digestive Endoscopy · doi:10.1111/den.12269 · Cited by 30
Small bowel diagnostics: Current place of small bowel endoscopy
Aktaş, H., & Mensink, P. (2012) · Best Practice & Research Clinical Gastroenterology · doi:10.1016/j.bpg.2012.03.007 · Cited by 30
Guo, Y. P., Zhang, S., Ritter, A., & Man, H. (2013) · IEEE Transactions on Education · doi:10.1109/te.2013.2281025 · Cited by 30
Capsule endoscopy: current indications and future prospects
Remedios, M. L., & Appleyard, M. N. (2005) · Internal Medicine Journal · doi:10.1111/j.1445-5994.2005.00808.x · Cited by 30
The First International Workshop on Double Balloon Endoscopy: a consensus meeting report
Sugano, K., & Marcon, N. E. (2007) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2007.02.020 · Cited by 30
Intestinal strictures can impede wireless capsule enteroscopy
Jonnalagadda, S. S., & Gyawali, C. P. (2003) · Gastrointestinal Endoscopy · doi:10.1067/mge.2003.128 · Cited by 30
Schulmann, K., & Schmiegel, W. (2004) · Gastrointestinal Endoscopy Clinics of North America · doi:10.1016/j.giec.2003.10.014 · Cited by 30
Turan, M., Almalıoğlu, Y., Gilbert, H. B., Araújo, H. J., Cemgil, A. T., & Sitti, M. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8460472 · Cited by 29
Multiple bleeding detection in wireless capsule endoscopy
Bchir, O., Ismail, M. M. B., & Alzahrani, N. (2018) · Signal Image and Video Processing · doi:10.1007/s11760-018-1336-3 · Cited by 29
High Data Rate Communications In Vivo Using Ultrasound
Kou, Z., Miller, R. J., Singer, A. C., & Oelze, M. L. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3070477 · Cited by 29
Autonomous navigation of a magnetic colonoscope using force sensing and a heuristic search algorithm
Huang, H.-E., Yen, S.-Y., Chu, C.-F., Suk, F., Lien, G., & Liu, C. (2021) · Scientific Reports · doi:10.1038/s41598-021-95760-7 · Cited by 29
Efficient Power Receiving Coil With Novel Ferrite Core Structure for Capsule Robot
Zhuang, H., Wang, W., Zhao, K., Kuang, S., Wang, Z., & Yan, G. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3200524 · Cited by 29
LoGuidice, A., Ramírez‐Alcántara, V., Proli, A. J., Gavillet, B., & Boelsterli, U. A. (2010) · Toxicological Sciences · doi:10.1093/toxsci/kfq226 · Cited by 29
Design of a Tunable All-Digital UWB Pulse Generator CMOS Chip for Wireless Endoscope
Kim, C., & Nooshabadi, S. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2037490 · Cited by 29
Poon, C. C. Y., Leung, B. C. S., Chan, C. K. W., Lau, J. Y. W., & Chiu, P. W. Y. (2015) · Surgical Endoscopy · doi:10.1007/s00464-015-4224-8 · Cited by 29
Pietri, O., Rezgui, G., Histace, A., Camus, M., Nion–Larmurier, I., Li, C., Becq, A., Ali, E. A., Romain, O., Chaput, U., et al. (2018) · Endoscopy International Open · doi:10.1055/a-0573-1044 · Cited by 29
Characteristic Analysis of a Magnetically Actuated Capsule Microrobot in Medical Applications
Cai, Z., Fu, Q., Zhang, S., Guo, S., Guo, J. J., Zhang, X., & Fan, C. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3130299 · Cited by 29
Gay, G., Delvaux, M. M., & Frédéric, M. (2008) · World Journal of Gastroenterology · doi:10.3748/wjg.14.5237 · Cited by 29
Ingestible Gastrointestinal Sampling Devices: State-of-the-Art and Future Directions
Amoako-Tuffour, Y., Jones, M. L., Shalabi, N., Labbé, A., Srikar, V. T., & Prakash, S. (2014) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2014010846 · Cited by 29
Unsupervised summarisation of capsule endoscopy video
Iakovidis, D. K., Tsevas, S., Maroulis, D., & Polydorou, A. A. (2008) · IEEE International Conference on Intelligent Systems · doi:10.1109/is.2008.4670414 · Cited by 29
A Magnetic Stereo-Actuation Mechanism for Active Capsule Endoscope
Wang, X., & Meng, M. Q. ‐. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352913 · Cited by 29
Intestinal allergy expels hookworms: seeing is believing
Croese, J., & Speare, R. (2006) · Trends in Parasitology · doi:10.1016/j.pt.2006.09.010 · Cited by 29
Endogenous heparinoids in acute variceal bleeding: Figure 1
Thalheimer, U., Triantos, C. K., Samonakis, D. N., Patch, D., Burroughs, A. K., Riddell, A. F., & Perry, D. J. (2005) · Gut · doi:10.1136/gut.2004.051474 · Cited by 29
Capsule robots for the monitoring, diagnosis, and treatment of intestinal diseases
Wei, X., Xi, P., Chen, M., Wen, Y., Wu, H., Wang, L., Zhu, Y., Ren, Y., & Gu, Z. (2024) · Materials Today Bio · doi:10.1016/j.mtbio.2024.101294 · Cited by 28
Terahertz Antenna Technology for Imaging and Sensing Applications
Malhotra, I., & Singh, G. K. (2021) · Springer eBooks · doi:10.1007/978-3-030-68960-5 · Cited by 28
Son, G., Eo, T., An, J., Oh, D. J., Shin, Y., Rha, H., Kim, Y. J., Lim, Y. J., & Hwang, D. (2022) · Diagnostics · doi:10.3390/diagnostics12081858 · Cited by 28
Wu, S., Zhang, R., Yan, J., Li, C., Liu, Q., Wang, L., & Wang, H. (2023) · Bioengineering · doi:10.3390/bioengineering10121416 · Cited by 28
Diagnostic Yield of Repeat Capsule Endoscopy and the Effect on Subsequent Patient Management
Svarta, S., Segal, B., Law, J. K., Sandhar, A., Kwok, R. W., Jacques, A., Lakzadeh, P., & Enns, R. A. (2010) · Canadian Journal of Gastroenterology · doi:10.1155/2010/382301 · Cited by 28
Capsule enteroscopy and radiology of the small intestine
Fork, F., & Aabakken, L. (2007) · European Radiology · doi:10.1007/s00330-007-0718-7 · Cited by 28
A robotic endoscope based on minimally invasive locomotion and wireless techniques for human colon
Gao, P., Yan, G., Wang, Z., Wang, K., Jiang, P., & Zhou, Y. (2011) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.389 · Cited by 28
Higuchi, K., Komatsu, K., Wakamatsu, H., Kawasaki, H., Murata, M., Miyazaki, K., Oikawa, K., Ohwada, M., Nanjo, H., Otaka, M., et al. (2007) · Internal Medicine · doi:10.2169/internalmedicine.46.6087 · Cited by 28
A general framework for wireless capsule endoscopy study synopsis
Zhao, Q., Mullin, G. E., Meng, M. Q. ‐., Dassopoulos, T., & Kumar, R. (2014) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2014.05.011 · Cited by 28
Capsule endoscopy in pediatric patients
Shamir, R., & Eliakim, R. (2008) · World Journal of Gastroenterology · doi:10.3748/wjg.14.4152 · Cited by 28
An ultrawideband conformal loop antenna for ingestible capsule endoscope system
Suzan, M. M., Haneda, K., Icheln, C., Khatun, A., & Takizawa, K. (2016) · European Conference on Antennas and Propagation · doi:10.1109/eucap.2016.7481526 · Cited by 28
Turan, M., Almalıoğlu, Y., Örnek, E. P., Araújo, H. J., Yanik, M. F., & Sitti, M. (2018) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2018.8594485 · Cited by 28
Mabry, K., Hill, T. L., Marks, S. L., & Hardy, B. T. (2019) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.15584 · Cited by 28
A Fluorescence-Based Wireless Capsule Endoscopy System for Detecting Colorectal Cancer
Alam, M. W., Vedaei, S. S., & Wahid, K. A. (2020) · Cancers · doi:10.3390/cancers12040890 · Cited by 28
WCE polyp detection with triplet based embeddings
Laiz, P., Vitria, J. M., Wenzek, H. R., Malagelada, C., Azpiroz, F., & Seguí, S. (2020) · Dipòsit Digital de la Universitat de Barcelona (Universitat de Barcelona) · Cited by 28
Capsule Endoscopy for Gastric Evaluation
Kim, J. H., & Nam, S. (2021) · Diagnostics · doi:10.3390/diagnostics11101792 · Cited by 28
Video capsule endoscopy is successful and effective in outpatients with implantable cardiac devices
Stanich, P. P., Kleinman, B. M., Betkerur, K., Oza, N. M., Porter, K. M., & Meyer, M. M. (2014) · Digestive Endoscopy · doi:10.1111/den.12288 · Cited by 28
Automatic frame reduction of Wireless Capsule Endoscopy video
Tsevas, S., Iakovidis, D. K., Maroulis, D., & Pavlakis, E. (2008) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe.2008.4696805 · Cited by 28
Rauch, S., Krueger, K. J., Turan, A., Roewer, N., & Sessler, D. I. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1415-6 · Cited by 28
Outcomes after symptomatic capsule retention in suspected small bowel obstruction
Sîngeap, A.-M., Trifan, A. V., Cojocariu, C., Sfarti, C. V., & Stanciu, C. (2011) · European Journal of Gastroenterology & Hepatology · doi:10.1097/meg.0b013e328349efa4 · Cited by 28
Inhibition of Bach1 ameliorates indomethacin-induced intestinal injury in mice.
Harusato, A., Naito, Y., Takagi, T., Yamada, S., Mizushima, K., Hirai, Y., Horie, R., Inoue, K., Fukumoto, K., Hirata, I., et al. (2009) · PubMed · Cited by 28
Smart optical CMOS sensor for endoluminal applications
Vatteroni, M., Covi, D., Cavallotti, C., Clementel, L., Valdastri, P., Menciassi, A., Dario, P., & Sartori, A. (2010) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2010.03.034 · Cited by 28
CT enterography vs. capsule endoscopy
Boriskin, H. S., DeVito, B., Hines, J. J., Jr., Scarmato, V. J., & Friedman, B. (2008) · Abdominal Imaging · doi:10.1007/s00261-008-9404-8 · Cited by 28
Smaller, Softer, Safer, Smarter Robots
Wood, R. J., & Walsh, C. J. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3006949 · Cited by 28
Artificial intelligence and capsule endoscopy: Is the truly “smart” capsule nearly here?
Byrne, M. F., & Donnellan, F. K. (2018) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2018.08.017 · Cited by 28
FD-Vision Mamba for Endoscopic Exposure CorrectionPreprint
Zheng, Z., & Zhang, J. (2024) · arXiv (Cornell University) · doi:10.48550/arxiv.2402.06378 · Cited by 28
Koulaouzidis, A., Karargyris, A., Rondonotti, E., Noble, C. L., Douglas, S., Alexandridis, E., Zahid, A. M., Bathgate, A. J., Trimble, K. C., & Plevris, J. N. (2013) · Digestive and Liver Disease · doi:10.1016/j.dld.2013.05.013 · Cited by 27
Chu, H., Wang, P.-J., Zhu, X., & Hong, H. (2019) · IEEE Access · doi:10.1109/access.2019.2891880 · Cited by 27
Abnormality classification in small datasets of capsule endoscopy images
da Fonseca, F. R., Nunes, B., Salgado, M., & Cunha, A. M. T. D. S. (2022) · Procedia Computer Science · doi:10.1016/j.procs.2021.12.038 · Cited by 27
Automated evaluation of colon capsule endoscopic severity of ulcerative colitis using ResNet50
Higuchi, N., Hiraga, H., Sasaki, Y., Hiraga, N., Igarashi, S., Hasui, K., Ogasawara, K., Maeda, T., Murai, Y., Tatsuta, T., et al. (2022) · PLoS ONE · doi:10.1371/journal.pone.0269728 · Cited by 27
Fundamentals of Bowel Cancer for Biomedical Engineers
Tian, J., Afebu, K. O., Bickerdike, A., Liu, Y., Prasad, S., & Nelson, B. J. (2023) · Annals of Biomedical Engineering · doi:10.1007/s10439-023-03155-8 · Cited by 27
Frontiers in Intelligent Colonoscopy
Ji, G.-P., Liu, J., Xu, P., Barnes, N. M., Khan, F. S., Khan, S. H., & Fan, D.-P. (2026) · Machine Intelligence Research · doi:10.1007/s11633-025-1597-6 · Cited by 27
Analysis of Robotic Locomotion Devices for the Gastrointestinal Tract
Phee, S. J., Menciassi, A., Accoto, D., Stefanini, C., & Dario, P. (2007) · Springer eBooks · doi:10.1007/3-540-36460-9_31 · Cited by 27
Itoh, S., Kawahito, S., & Terakawa, S. (2006) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2006.1693344 · Cited by 27
Metadata
- Authors
- Iddan, G., Meron, G., Glukhovsky, A., & Swain, P.
- Affiliations
- Royal London Hospital (GB)
- Venue
- Nature
- Published
- 2000-05-25
- Volume
- 405
- Issue
- 6785
- Pages
- 417-417
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W1650175677
- Semantic Scholar
- 1ca271343e306e1da8d8691766aeb6f7fbf74add
- Cited by
- 3,066
- References
- 4
- Citations by year
- 2026: 87 · 2025: 96 · 2024: 110 · 2023: 127 · 2022: 137 · 2021: 141 · 2020: 134 · 2019: 119 · 2018: 121 · 2017: 118 · 2016: 130 · 2015: 134 · 2014: 139 · 2013: 148 · 2012: 157
- FWCI
- 31.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Health Sciences › Medicine › Gastroenterology › Gastrointestinal Bleeding Diagnosis and Treatment
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Health Sciences › Medicine › Surgery › Minimally Invasive Surgical Techniques
- Keywords
- capsule endoscopy, small bowel imaging, gastrointestinal endoscopy
- MeSH terms
- Capsules, Humans, Miniaturization, Transistors, Electronic, Video-Assisted Surgery
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.