The DOI matches its Crossref record.
High Accuracy of Narrow Band Imaging Without Magnification for the Real-Time Characterization of Polyp Histology and Its Comparison With High-Definition White Light Colonoscopy: A Prospective Study
Abstract
OBJECTIVES: Standard white light colonoscopy has limited ability to differentiate between polyp types (adenomatous vs. hyperplastic). Narrow band imaging (NBI) highlights the superficial mucosal/vascular patterns on polyps and may facilitate real-time characterization of polyp histology. The aim of this study was to prospectively evaluate and compare the diagnostic characteristics of high-definition white light colonoscopy (HDWL) and NBI without magnification in the real-time prediction of polyp histology (adenomatous vs. hyperplastic) by evaluating the surface mucosal and vascular patterns. METHODS: We conducted a prospective comparative study in a tertiary referral center. A total of 100 patients referred for screening or surveillance colonoscopy were prospectively enrolled and underwent colonoscopy using a high-definition colonoscope with NBI capability. Every polyp detected was initially evaluated with HDWL followed by NBI for the presence of surface mucosal/vascular patterns. Based on these patterns, polyp histology was predicted by both modalities. The main outcome measurements were: (i) diagnostic characteristics of HDWL and NBI in predicting polyp histology and (ii) impact of polyp size and learning effect (first half of study vs. second half) on the ability of NBI to predict adenomas. RESULTS: A total of 236 polyps were detected in 100 patients-143 adenomas, 77 hyperplastic, and 16 others. Surface patterns (type A: hyperplastic; type B: adenomatous) were recognized in all polyps with NBI (100%) compared to 45% with HDWL. For predicting adenomas, NBI had a significantly higher sensitivity and greater accuracy (96 and 93% respectively) compared with HDWL (38 and 61% respectively) (all P<0.0001). Although the accuracy of NBI for predicting adenomas improved with increasing polyp size (< or =5 mm; 6-9 mm; > or =10 mm) and in the second half compared with the first half of the study, these differences were not statistically significant. CONCLUSIONS: Using a simple surface mucosal/vascular pattern classification, NBI without magnification was highly accurate and significantly superior to HDWL for the real-time prediction of adenomas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hewett, D. G., Kaltenbach, T., Sano, Y., Tanaka, S., Saunders, B. P., Ponchon, T., Soetikno, R., & Rex, D. K. (2012) · Gastroenterology · doi:10.1053/j.gastro.2012.05.006 · Cited by 592
Hayashi, N., Tanaka, S., Hewett, D. G., Kaltenbach, T. R., Sano, Y., Ponchon, T., Saunders, B. P., Rex, D. K., & Soetikno, R. M. (2013) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2013.04.185 · Cited by 485
Ignjatovic, A., East, J. E., Suzuki, N., Vance, M., Guenther, T., & Saunders, B. P. (2009) · The Lancet Oncology · doi:10.1016/s1470-2045(09)70329-8 · Cited by 368
A Resect and Discard Strategy Would Improve Cost-Effectiveness of Colorectal Cancer Screening
Hassan, C., Pickhardt, P. J., & Rex, D. K. (2010) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2010.05.018 · Cited by 296
Ladabaum, U., Fioritto, A., Mitani, A., Desai, M., Kim, J. P., Rex, D. K., Imperiale, T., & Gunaratnam, N. (2013) · Gastroenterology · doi:10.1053/j.gastro.2012.09.054 · Cited by 224
Metadata
- Authors
- Rastogi, A., Keighley, J., Singh, V., Callahan, P., Bansal, A., Wani, S., & Sharma, P.
- Venue
- The American Journal of Gastroenterology
- Published
- 2009-07-07
- Volume
- 104
- Issue
- 10
- Pages
- 2422-2430
- ISSN
- 0002-9270 (ISSN-L)
- 1572-0241
- OpenAlex
- W2045319859
- Cited by
- 170
- References
- 0
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High Accuracy of Narrow Band Imaging Without Magnification for the Real-Time Characterization of Polyp Histology and Its Comparison With High-Definition White Light Colonoscopy: A Prospective Study. https://app.cochat.ai/papers/10.1038/ajg.2009.403
- The paper
- Rastogi, A., Keighley, J., Singh, V., Callahan, P., Bansal, A., Wani, S., & Sharma, P. (2009). High Accuracy of Narrow Band Imaging Without Magnification for the Real-Time Characterization of Polyp Histology and Its Comparison With High-Definition White Light Colonoscopy: A Prospective Study. The American Journal of Gastroenterology. https://doi.org/10.1038/ajg.2009.403
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.