CoChat

Capsule Endoscopy Has a Significantly Higher Diagnostic Yield in Patients With Suspected and Established Small-Bowel Crohn's Disease: A Meta-Analysis

Dionisio, Paula M, Gurudu, Suryakanth R, Leighton, Jonathan A, Leontiadis, Grigoris I, Fleischer, David E, Hara, Amy K, Heigh, Russell I, Shiff, Arthur D, Sharma, Virender K · 2010 · American Journal of Gastroenterology
Cited by 395

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: Capsule endoscopy (CE) has demonstrated superior performance compared with other modalities in its ability to detect early small-bowel (SB) Crohn's disease (CD), especially when ileoscopy is negative or unsuccessful. The aim of this study was to evaluate the diagnostic yield of CE compared with other modalities in patients with suspected and established CD using a meta-analysis. METHODS: A thorough literature search for prospective studies comparing the diagnostic yield of CE with other modalities in patients with CD was undertaken. Other modalities included push enteroscopy (PE), colonoscopy with ileoscopy (C+IL), SB radiography (SBR), computed tomography enterography (CTE), and magnetic resonance enterography (MRE). Data on diagnostic yield among various modalities were extracted, pooled, and analyzed. Data on patients with suspected and established CD were analyzed separately. Weighted incremental yield (IYW) (diagnostic yield of CE-diagnostic yield of comparative modality) and 95% confidence intervals (CIs) of CE over comparative modalities were calculated. RESULTS: A total of 12 trials (n=428) compared the yield of CE with SBR in patients with CD. Eight trials (n=236) compared CE with C+IL, four trials (n=119) compared CE with CTE, two trials (n=102) compared CE with PE, and four trials (n=123) compared CE with MRE. For the suspected CD subgroup, several comparisons met statistical significance. Yields in this subgroup were CE vs. SBR: 52 vs. 16% (IYw=32%, P<0.0001, 95% CI=16-48%), CE vs. CTE: 68 vs. 21% (IYw=47%, P<0.00001, 95% CI=31-63%), and CE vs. C+IL: 47 vs. 25% (IYw=22%, P=0.009, 95% CI=5-39%). Statistically significant yields for CE vs. an alternate diagnostic modality in established CD patients were seen in CE vs. PE: 66 vs. 9% (IYw=57%, P<0.00001, 95% CI=43-71%), CE vs. SBR: 71 vs. 36% (IYw=38%, P<0.00001, 95% CI=22-54%), and in CE vs. CTE: 71 vs. 39% (IYw=32%, P=or<0.0001, 95% CI=16-47%). CONCLUSIONS: Our meta-analysis demonstrates that CE is superior to SBR, CTE, and C+IL in the evaluation of suspected CD patients. CE is also a more effective diagnostic tool in established CD patients compared with SBR, CTE, and PE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ajg.2009.713

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 395

Metadata

Authors
Dionisio, P. M., Gurudu, S. R., Leighton, J. A., Leontiadis, G. I., Fleischer, D. E., Hara, A. K., Heigh, R. I., Shiff, A. D., & Sharma, V. K.
Venue
American Journal of Gastroenterology
Published
2010-06
Volume
105
Issue
6
Pages
1240-1248
ISSN
0002-9270 (ISSN-L)
OpenAlex
W1989038797
Cited by
395
References
7
FWCI
2.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.