CoChat

A Novel Method for the Nonradiological Assessment of Ineffective Swallowing

Omari, Taher I, Dejaeger, Eddy, Van Beckevoort, Dirk, Goeleven, Ann, De Cock, Paul, Hoffman, Ilse, Smet, Maria H, Davidson, Geoffrey P, Tack, Jan, Rommel, Nathalie · 2011 · American Journal of Gastroenterology
Cited by 106

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: This validation study evaluates a new manometry impedance-based approach for the objective assessment of pharyngeal function relevant to postswallow bolus residue. METHODS: We studied 23 adult and pediatric dysphagic patients who were all referred for a videofluoroscopy, and compared these patients with 10 adult controls. The pharyngeal phase of swallowing of semisolid boluses was recorded with manometry and impedance. Fluoroscopic evidence of postswallow bolus residue was scored. Pharyngeal pressure impedance profiles were analyzed. Computational algorithms measured peak pressure (Peak P), pressure at nadir impedance (PNadImp), time from nadir impedance to PeakP (PNadImp-PeakP), the duration of impedance drop in the distal pharynx (flow interval), upper esophaghageal sphincter (UES) relaxation interval (UES-RI), nadir UES pressure (NadUESP), UES intrabolus pressure (UES-IBP), and UES resistance. A swallow risk index (SRI) was derived by the formula: SRI=(FI × PNadImp)/(PeakP × (TNadImp-PeakP+1)) × 100. RESULTS: In all, 76 patient swallows (35 with residue) and 39 control swallows (12 with residue) were analyzed. Different functional variables were found to be altered in relation to residue. In both controls and patients, flow interval was longer in relation to residue. In controls, but not patients, residue was associated with an increased PNadImp (suggestive of increased pharyngeal IBP). Controls with residue had increased UES-IBP, NadUESP, and UES resistance compared with patients with residue. Residue in patients was related to a prolonged UES-RI. The SRI was elevated in relation to residue in both controls and patients and an average SRI of 9 was optimally predictive of residue (sensitivity 75% and specificity 80%). CONCLUSIONS: We present novel findings in control subjects and dysphagic patients showing that combined manometry and impedance recordings can be objectively analyzed to derive pressure-flow variables that are altered in relation to the bolus residual and can be combined to predict ineffective pharyngeal swallowing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ajg.2011.143

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 106

Metadata

Authors
Omari, T. I., Dejaeger, E., Van Beckevoort, D., Goeleven, A., De Cock, P., Hoffman, I., Smet, M. H., Davidson, G. P., Tack, J., & Rommel, N.
Venue
American Journal of Gastroenterology
Published
2011-10
Volume
106
Issue
10
Pages
1796-1802
ISSN
0002-9270 (ISSN-L)
OpenAlex
W2135822007
Cited by
106
References
2
FWCI
19.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.