Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 249

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Optimizing Adequacy of Bowel Cleansing for Colonoscopy: Recommendations From the US Multi-Society Task Force on Colorectal Cancer

Johnson, David A, Barkun, Alan N, Cohen, Larry B, Dominitz, Jason A, Kaltenbach, Tonya, Martel, Myriam, Robertson, Douglas J, Boland, Richard C, Giardello, Frances M, Lieberman, David A, Levin, Theodore R, Rex, Douglas K · 2014 · American Journal of Gastroenterology

Abstract

Colorectal cancer (CRC) is the second leading cause of cancer-related deaths in the United States (1) Colonoscopy can prevent CRC by the detection and removal of precancerous lesions. In addition to CRC screening and surveillance, colonoscopy is used widely for the diagnostic evaluation of symptoms and other positive CRC screening tests. Regardless of indication, the success of colonoscopy is linked closely to the adequacy of preprocedure bowel cleansing. Unfortunately, up to 20–25% of all colonoscopies are reported to have an inadequate bowel preparation (2, 3) The reasons for this range from patient-related variables such as compliance with preparation instructions and a variety of medical conditions that make bowel cleansing more difficult to unit-specific factors (eg, extended wait times after scheduling of colonoscopy) (4) Adverse consequences of ineffective bowel preparation include lower adenoma detection rates, longer procedural time, lower cecal intubation rates, increased electrocautery risk, and shorter intervals between examinations (3, 5, 6, 7) Bowel preparation formulations intended for precolonoscopy cleansing are assessed based on their efficacy, safety, and tolerability. Lack of specific organ toxicity is considered to be a prerequisite for bowel preparations. Between cleansing efficacy and tolerability, however, the consequences of inadequate cleansing suggest that efficacy should be a higher priority than tolerability. Consequently, the choice of a bowel cleansing regimen should be based on cleansing efficacy first and patient tolerability second. However, efficacy and tolerability are closely interrelated. For example, a cleansing agent that is poorly tolerated and thus not fully ingested may not achieve an adequate cleansing. The goals of this consensus document are to provide expert, evidence-based recommendations for clinicians to optimize colonoscopy preparation quality and patient safety. Recommendations are provided using the Grades of Recommendation Assessment, Development and Evaluation (GRADE) scoring system, which weighs the strength of the recommendation and the quality of the evidence (8) Methods Search Strategy Computerized medical literature searches were conducted from January 1980 (first year of approval of polyethylene glycol–electrolyte lavage solution [PEG-ELS]–based preparation by the Food and Drug Administration [FDA]) up to August 2013 using MEDLINE, PubMed EMBASE, Scopus, CENTRAL, and ISI Web of knowledge. We used a highly sensitive search strategy to identify reports of randomized controlled trials (9) with a combination of medical subject headings adapted to each database and text words related to colonoscopy and gastrointestinal agents, bowel preparation, generic name, and brand name. The complete search terms are available in Appendix A. Recursive searches and cross-referencing also were performed using a “similar articles” function; hand searches of articles were identified after an initial search. We included all fully published adult human studies in English or French. A systematic review of published articles and abstracts presented at national meetings was performed to collect and select the evidence. A meta-analysis and consensus agreement were used to analyze the evidence. Expert consensus was used to formulate the recommendations. The GRADE system was used to rate the strength of the recommendations. The guideline was reviewed by committees of and approved by the governing boards of the member societies of the Multi-Society Task Force on Colorectal Cancer (American College of Gastroenterology, American Gastroenterological Association, and American Society of Gastrointestinal Endoscopy). Effect of inadequate preparation on polyp/adenoma detection and recommended follow-up intervals Recommendations Preliminary assessment of preparation quality should be made in the rectosigmoid colon, and if the indication is screening or surveillance and the preparation clearly is inadequate to allow polyp detection greater than 5 mm, the procedure should be either terminated and rescheduled or an attempt should be made at additional bowel cleansing strategies that can be delivered without cancelling the procedure that day (Strong recommendation, low-quality evidence). If the colonoscopy is complete to cecum, and the preparation ultimately is deemed inadequate, then the examination should be repeated, generally with a more aggressive preparation regimen, within 1 year; intervals shorter than 1 year are indicated when advanced neoplasia is detected and there is inadequate preparation (Strong recommendation, low-quality evidence). If the preparation is deemed adequate and the colonoscopy is completed then the guideline recommendations for screening or surveillance should be followed (Strong recommendation, high-quality evidence). Inadequate colonic preparation is associated with reduced adenoma detection rates (ADRs). A large prospective European study of 5832 patients enr

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ajg.2014.272

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 249

Metadata

Authors
Johnson, D. A., Barkun, A. N., Cohen, L. B., Dominitz, J. A., Kaltenbach, T., Martel, M., Robertson, D. J., Boland, R. C., Giardello, F. M., Lieberman, D. A., Levin, T. R., & Rex, D. K.
Venue
American Journal of Gastroenterology
Published
2014-10
Volume
109
Issue
10
Pages
1528-1545
ISSN
0002-9270 (ISSN-L)
OpenAlex
W1539086707
Cited by
249
References
2
FWCI
9.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optimizing Adequacy of Bowel Cleansing for Colonoscopy: Recommendations From the US Multi-Society Task Force on Colorectal Cancer. https://app.cochat.ai/papers/10.1038/ajg.2014.272
The paper
Johnson, D. A., Barkun, A. N., Cohen, L. B., Dominitz, J. A., Kaltenbach, T., Martel, M., Robertson, D. J., Boland, R. C., Giardello, F. M., Lieberman, D. A., Levin, T. R., & Rex, D. K. (2014). Optimizing Adequacy of Bowel Cleansing for Colonoscopy: Recommendations From the US Multi-Society Task Force on Colorectal Cancer. American Journal of Gastroenterology. https://doi.org/10.1038/ajg.2014.272

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.